3.Locate the Clear CMOS/Recovery jumper on the system board. See “Identifying parts on the system board” on page 83.
4.If necessary, see “Installing adapters” on page 85 to remove any adapters that impede access to the Clear CMOS/Recovery jumper.
5.Move the jumper from the standard position (pins 1 and 2) to the maintenance or configure position (pins 2 and 3).
6.Replace the cover and connect the power cord. See “Replacing the cover and connecting the cables.”
7.Restart the computer, leave it on for approximately 10 seconds. Turn off the computer by holding the power switch for approximately 5 seconds. The computer will turn off.
8.Repeat steps 2 through 4 on page 95.
9.Move the jumper back to the standard (pins 1 and 2).
10.Replace the cover and connect the power cord. See “Replacing the cover and connecting the cables.”
Replacing the cover and connecting the cables
After working with options, you need to install any removed parts, replace the cover, and reconnect any cables, including telephone lines and power cords. Also, depending on the option that is installed, you might need to confirm the updated information in the IBM Setup Utility program.
To replace the cover and connect cables to your computer:
1.Ensure that all components have been reassembled correctly and that no tools or loose screws are left inside your computer.
2.Clear any cables that might impede the replacement of the cover.
3.Position the cover on the chassis so that the rail guides on the bottom of the cover engage the rails and push the cover closed until it latches.
4.Reconnect the external cables and power cords to the computer. See “Installing external options” on page 78.