Physical Characteristics | Coupling Facility — CF Level of Support |
z890 Power/Heating/Cooling
System Power Consumption (50/60 Hz, KVA)
Model / Config | 1 I/O Cage |
A04 | 1.5 - 4.7 |
Note: Assumes 60 amp cords |
System Cooling (Air Flow Rate - CFM)
Model / Config | 1 I/O Cage |
A04 | 640 |
Note: Assumes chilled underfl oor temperature of 24OC |
Heat Output (kBTU/hr)
Model / Config | 1 I/O Cage |
A04 | 5.12 - 16.06 |
z890 Dimensions
| z890 |
# of Frames | 1 Frame |
| IBF contained within the single frame |
Height (w/ covers) | 194.1 cm / 76.4 in (40 EIA) |
Width (w/ covers) | 78.5 cm / 30.9 in |
Depth (w/ covers) | 157.7 cm / 62.1 in |
Height Reduction | 178.5 cm / 70.3 in (38 EIA) |
Width Reduction | None |
Machine Area | 1.24 sq. meters / 13.31 sq. feet |
Service Clearance | 3.03 sq. meters / 32.61 sq. feet |
| (IBF contained within the frame) |
|
|
CF Level | Function |
|
|
14Contains modifi cations to the CF dispatcher and internal serialization mechanisms to better manage coupled workloads in all environments.
CFCC Level 14 with CFCC Dispatcher Modifi ca- tions is exclusive to z890 and z990
13Parallel Sysplex performance enhancements for DB2 castout processing and receives the benefi ts of CFCC enhanced patch apply
12
Enhanced Storage Protect
DB2 Performance
Message Time Ordering
119672 G5/G6 CF Duplexing
Toleration for >15 LPAR ID on z990, z890
10z900 GA2 support
9MQSeries® shared message queues WLM
8Dynamic ICF expansion into shared ICF pool
7Shared ICF partitions on server models DB2 Delete Name optimization
6ICB & IC TPF support
5DB2 cache structure duplexing
DB2 castout performance improvement Dynamic ICF expansion into shared CP pool*
4Performance optimization for IMS & VSAM RLS Dynamic CF Dispatching
Internal Coupling Facility*
IMS shared message queue extensions
3IMS shared message queue base
2DB2 performance
VSAM RLS
255 Connectors/1023 structures for IMS Batch DL1
1Dynamic Alter support
CICS temporary storage queues System Logger
Notes:
–G5 base CF level code is CF Level 6 and can be upgraded to CF Level 11
–G6 base CF level code is CF Level 8 and can be upgraded to CF Level 11
–z900 base CF level code is CF Level 9
–z800, z890 and z990 base CF level code is CF Level 12
–Detailed information regarding CF Levels can be found in Coupling Facility Level (CF LEVEL) Considerations at ibm.com/s390/pso/cftable.html
*G3, G4, G5 and G6 only **zSeries required
Please note that although a particular back level machine may be updated to a more current CFCC level, NOT all the functions of that CFCC level may be able to run on that hardware platform, i.e., G3/G4 can be upgraded to CF Level 8 but it cannot use dynamic ICF expansion into shared ICF pool.
60