IBM manual zSeries 890 Family Configuration Detail, Processor Unit Assignments, Processor Memory

Models: 890

1 94
Download 94 pages 54.16 Kb
Page 58
Image 58
zSeries 890 Family Configuration Detail

zSeries 890 Family Configuration Detail

Maximum of 512 CHPIDs; One I/O cages: 28 I/O slots

 

 

Per System

 

 

 

 

 

 

 

 

Feature

Minimum

Maximum

Maximum

Ports/

Purchase

 

Features

I/O Slots

Connections

Channels/

Increments

 

 

used by

 

Increments

 

 

 

Features

 

per Feature

 

ESCON,

01

28

420

16

4

16 port

 

 

channels

channels2

channels3

FICON

01

204

80

4

1 feature

Express2

 

 

channels

channels

 

STI-35

0

8

N/A

2 outputs

N/A

ICB-3 link

01

N/A

16 links6

N/A

1 link

ICB-4 link

01

N/A7

8 links6

N/A

1 link

ISC-3

01

12

48 links6, 8

4 links

1 link9

OSA-

0

204

40

2

1 feature

Express

 

 

ports

ports

 

OSA-

0

202, 4

40

2 or 1 (10

1 feature

Express2

 

 

ports

GbE has 1)

 

Crypto

0

162, 4

16

2

1 feature

Express2

 

 

coprocessors

coprocessors

 

PCICA

0

24

4 accelerator

2 accelerator

1 feature

 

 

 

cards

cards

 

PCIXCC

010

44

4

1

1 feature10

 

 

 

coprocessor

coprocessor

 

 

 

 

 

 

 

1)A minimum of one I/O feature (ESCON, FICON Express/FICON Express2) or one Coupling Link (ICB, ISC-3) is required.

2)Each ESCON feature has 16 channels of which 15 channels may be acti- vated. One channel is always reserved as a spare.

3)ESCON channels are purchased in increments of four and are activated via Licensed Internal Code, Configuration Control (LIC CC). Channels are activated equally across all installed 16-port ESCON features for high availability.

4)The maximum quantity of FICON Express, FICON Express2, OSA- Express, OSA-Express2, PCICA, and PCIXCC in combination cannot exceed 20 features per server. When the FICON Express2 feature becomes available, the FICON Express (feature codes 2319 and 2320) will no longer be orderable.

5)Each STI-3 distribution card, which supports the ICB-3s, resides in the I/O cage, occupying one I/O slot.

6)The maximum number of Coupling Links combined (ICs, ICB-3s, ICB-4s, and active ISC-3 links) cannot exceed 64 per server.

7)ICB-4s do not require connectivity to a card in the I/O cage. ICB-4s are not included in the maximum feature count for I/O slots.

8)A maximum of 32 ISC-3s can be defi ned in compatibility mode (operat- ing at 1 Gbps, instead of 2 Gbps).

9)It is recommended that an initial order for ISC-3 include two links. When two links are purchased, two ISC-3 features are shipped and activated links are balanced across ISC-3 features for high availability.

10)PCIXCC feature increments are 0, 2, 3, or 4.

Note: The Capacity Model 110 has an I/O cage with 16 I/O slots maximum which will support up to 240 channels which can be any mix of the fol- lowing as long as it does not exceed 240 channels — maximum of 240 ESCON channels, 32 FICON Express channels, 24 OSA-Express ports.

Processor Unit Assignments

Model

Total PUs

Characterized PUs*

SAP Standard

Spares

A04***

 

 

 

 

1-way**

5

1

1

3

 

 

 

 

 

2-way**

5

2

1

2

 

 

 

 

 

3-way**

5

3

1

1

 

 

 

 

 

4-way**

5

4

1

0

 

 

 

 

 

*PU can be characterized as CP, IFL, ICF, or zAAP

**These values are for all machines including the sub-uni, sub 2-way models, etc.

***Customer will be required to purchase at least one CP, IFL, ICF or zAAP

Processor Memory

z890 Model

Minimum

Maximum

A04

8 GB

32 GB

Single memory card. Memory cards 8 GB, 16 GB or 32 GB. Memory incre- ments 8 GB.

Channels

Model

ESCON Min

**ESCON Max

*FICON Min

*FICON Max

A04

0

420

0

40

*FICON Express and FCP configured on the same FICON Express features. Max FICON Express channels total 40, max FICON Express2 channels total 80.

**ESCON increments of 4 channels

Coupling Links

Links

IC

 

ICB-3*

ICB-4

ISC-3

Max Links

 

0-32

 

0-16

0-8

0-48

Max combined IC,

 

 

 

 

 

 

ICB-3, ICB-4, active

 

 

 

 

 

 

ISC-3 = 64

*requires STI-3 card

 

 

 

 

 

 

 

 

 

 

 

Note: At least one I/O channel (FICON, ESCON) or one coupling link (ISC, ICB) must be present.

58

Page 58
Image 58
IBM zSeries 890 Family Configuration Detail, Processor Unit Assignments, Processor Memory, Channels, Coupling Links