Statement 8:
CAUTION:
Never remove the cover on a power supply or any part that has the following
label attached.
Hazardous voltage, current, and energy levels are present inside any
component that has this label attached. There are no serviceable parts inside
these components. If you suspect a problem with one of these parts, contact
a service technician.
Statement 30:
CAUTION:
To reduce the risk of electric shock or energy hazards:
vThis equipment must be installed by trained service personnel in a
restricted-access location, as defined by the NEC and IEC 60950-1, First
Edition, The Standard for Safety of Information Technology Equipment.
vConnect the equipment to a reliably grounded safety extra low voltage
(SELV) source.An SELV source is a secondary circuit that is designed so
that normal and single fault conditions do not cause the voltages to exceed
a safe level (60 V direct current).
vThe branch circuit overcurrent protection must be rated 20 A.
vUse 12 American Wire Gauge (AWG)or 2.5 mm2 copper conductor only, not
exceeding 4.5 meters in length.
vIncorporate a readily available approved and rated disconnect device in the
field wiring.
CAUTION:
This unit has more than one power source. To remove all power from the unit,
all dc MAINS must be disconnected.
Safety xvii