from the client to define itself to the library manager. If the storage agent is unable to define itself to the library manager, the storage agent must be defined manually using the DEFINE SERVER command issued from the library manager. For example:

define server storagnt serverpassword=fun4me hladdress=agent.tucson.ibm.com lladdress=1500

4.Configure a path to the library manager. If you need information about the commands, see the Administrator’s Reference.

If you are using a shared ACSLS library manager, configure a path to the library manager. This involves the following steps:

a.Define a library type of ACSLS. For example:

define library libmgr1 libtype=ACSLS shared=YES primarymanager=tsmsrvr

b.Define a path from the server to the library manager. For example: define path tsmsrver libmgr1 srctype=server desttype=library

c.Define a device class with a device type of SERVER. For example:

define devclass adeviceclassname library=alibraryname devtype=server servername=tsmsrvr

d.Define the storage pool. For example:

define stgpool apoolname adeviceclassname pooltype=primary

If you are using an ACSLS-managed external library, configure a path to the external library manager. This involves the following steps:

a.Define a library type of EXTERNAL. For example: define library stk-lib libtype=external

Note that if a library name remains constant but the library type changes from EXTERNAL to shared ACSLS, the storage agent must be stopped and restarted in order to recognize this change.

b.Define a path from the server to the external manager. Gresham EDT-DistribuTAPE is the external library manager interfacing with the ACSLS library software. The EDT executable is located in its default path /usr/lpp/dtelm/bin/elm. For example:

define path tsmsrver stk-lib srctype=server desttype=library externalmanager=/usr/lpp/dtelm/bin/elm

In the previous example, the path provided for the external manager depends on the operating system where the Tivoli Storage Manager server resides. For example:

vA Linux Tivoli Storage Manager server external manager path is /usr/dtelm/bin/elm.

vA Sun Solaris Tivoli Storage Manager server external manager path is /opt/OMIdtelm/bin/elm.

vA Windows Tivoli Storage Manager server external manager path is c:\program files\GES\EDT\bin\elm.exe.

c.Define a device class with a device type of ECARTRIDGE. For example:

define devclass adeviceclassname library=alibraryname devtype=ecartridge format=drive

Note: When you are using StorageTek 9840B tape devices with the z/OS data manager server, the FORMAT attribute of the device class must match the device type of the tape drive (that is, 9840B).

d.Define the storage pool. For example:

38IBM Tivoli Storage Manager for SAN for AIX: Storage Agent User’s Guide

Page 56
Image 56
IBM SC32-0129-00 manual Define the storage pool. For example

SC32-0129-00 specifications

The IBM SC32-0129-00 is a sophisticated component that plays a vital role in the realm of enterprise computing. Primarily designed for IBM's mid-range systems, it is known for its robust performance and reliability, serving as a critical part of data processing and storage architectures.

One of the main features of the SC32-0129-00 is its advanced input/output capabilities. This component supports a variety of connectivity options, enabling seamless integration within existing IT infrastructures. Its compatibility with multiple IBM systems ensures that organizations can enhance their current setups without needing to overhaul their entire technology stack.

The SC32-0129-00 utilizes cutting-edge technology to optimize data flow and accessibility. With its high-throughput design, it allows for rapid data transfer, facilitating efficient processing and retrieval. This is especially crucial in environments where large amounts of data are generated and need to be analyzed in real-time.

In terms of characteristics, the SC32-0129-00 is built with durability in mind. Its construction adheres to stringent quality standards, which means it can withstand the demands of high-volume operations. This resilience makes it a favored choice among businesses looking to maintain uptime and minimize disruptions.

Additionally, the SC32-0129-00 is designed with scalability in mind. As organizations grow and their data needs expand, this component can easily adapt to accommodate increased workloads. This flexibility is essential for businesses that must evolve with changing market conditions and technological advancements.

Another noteworthy aspect of the SC32-0129-00 is its energy efficiency. In an era where sustainability is paramount, efficient power consumption helps organizations reduce their carbon footprint while lowering operational costs. This aligns with IBM's commitment to creating environmentally friendly solutions.

In summary, the IBM SC32-0129-00 is a critical asset for businesses seeking to enhance their data processing capabilities. With its robust input/output features, high throughput, durability, scalability, and energy efficiency, it is engineered to serve the complex demands of today’s digital landscape. Investing in this component could lead to significant improvements in productivity and performance, making it a valuable addition to any enterprise system.