Symptom / Error FRU / Action in Sequence
601, 6XX
(601: Diskette drive or
controller error.)
1. Go to “Diskette Drive
Checkout” on
page 26.
2. CD-ROM and FDD
assembly
3. Diskette
4. Systemboard
602
(Diskette read error.) 1. Go to “Diskette Drive
Checkout” on
page 26.
2. Diskette
3. CD-ROM and FDD
assembly
604
(An unacceptable ID was
read from the diskette
drive.)
1. Go to “Diskette Drive
Checkout” on
page 26.
2. CD-ROM and FDD
assembly
3. Systemboard
11XX
1101: Serial_A test failure. 1.Serial device
2. Communicationcable
3. Systemboard
12XX
1201: Serial_B test failure. 1.System board
(infrared)
17XX
1701: Harddisk
controller failure.
1780,1790: Hard disk
0 error.
1781,1791: Hard disk
1 error.
1. Hard disk drive
2. Systemboard
24XX
(2401: System board video
error.)
System board
808X
8081: PCMCIA
presence test failure.
(PCMCIA revision
number also checked.)
8082: PCMCIA
registration test failure.
1. PC Card slot
assembly
2. PCMCIAdevice
3. Systemboard
860X
(Pointing device error when
TrackPoint III is disabled.)
8601: Systembus
error–8042 mouse
interface.
8602: Externalmouse
error.
8603: Systembus
error or mouse error.
1.External mouse
2. Externalkeyboard
3. Systemboard
IBM ThinkPad 380XD, 385XD (2635) 41