78
CHAPTER 5 CLOCK GENERATOR
5.6.2 CPU clock switching procedure
This section describes CPU clock switching procedure.
Figure 5-7. CPU Clock Switching
(1) The CPU is reset by setting the RESET signal to low level after power-on. After that, when reset is released
by setting the RESET signal to high level, main system clock starts oscillation. At this time, oscillation
stabilization time (217/fX) is secured automatically.
After that, the CPU starts executing the instruction at the minimum speed of the main system clock (12.8
ยต
s when
operated at 5.0 MHz).
(2) After the lapse of a sufficient time for the VDD voltage to increase to enable operation at maximum speeds,
the processor clock control register (PCC) and oscillation mode selection register (OSMS) are rewritten and
the maximum-speed operation is carried out.
VDD
RESET
CPU Clock
Wait (26.2 ms : 5.0 MHz)
Internal Reset Operation
Minimum
Speed
Operation
Maximum Speed
Operation