Flake Ice Machines | General Information |
Installation Guidelines
Note: Installation should be performed by an
Ambient Operating Temperatures
Minimum Operating Temperature: 50°F (10°C)
Maximum Operating Temperature 100°F (38°C), 110°F (43°C) on 50 Hz. Models.
Note:
Incoming Water Supply (See Plumbing Diagram for line sizing Page
Maximum incoming water temperature: 100°F (38°C)
Minimum incoming water pressure: 20 psi (1.4 bar)
Maximum incoming water pressure: 60 psi (4.1 bar)
Note: If water pressure exceeds 60 psi (4.1 bar), a water pressure regulator must be installed.
Drains:
Route bin drain, float drain and water condenser drain individually to a floor drain. The use of condensate pumps for draining water is not recommended by
Water Filtration
A water filter system should be installed with the ice machine.
Clearance Requirements
Self contained air cooled ice machines must have a minimum of 6 inches (15cm) of clearance around the entire machine.
Stacking
EF and EMF Series ice machines are not designed to be stacked.
Dispenser Application
EF and EMF Series ice machines are not designed to be placed on dispensers.
Electrical Specifications
The machine must be installed on a separate circuit.
Refer to the serial plate at the rear of the ice machine or the charts on Page A5.
Adjustments
Level the machine.
Check the primary and secondary bin control for proper adjustment, Page G3. Check the safety control for proper adjustment, Page G3.
Check the water in the water float for proper level, Page D1.
Check the water regulating valve adjustment if water cooled, Page F6.
Page A6