6-3 TRANSMIT ADJUSTMENT

Select an adjustment item using [] / [] keys, then set to the specified value using [] / [] keys on the connected PC’s keyboard.

ADJUSTMENT

ADJUSTMENT CONDITION

UNIT

OPERATION

 

 

 

VALUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

1

• Channel

: CH 5

Rear

Connect an RF power meter to

 

50 W [USA]

POWER

 

• Transmitting

 

panel

the antenna connector.

25 W [EUR], [EXP]

[Power (Hi)]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Power (L2)]

2

• Channel

: CH 6

 

 

 

25 W [USA]

 

 

 

• Transmitting

 

 

 

10 W [EUR], [EXP]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Power (L1)]

3

• Channel

: CH 3

 

 

 

5.0 W [USA]

 

 

 

• Transmitting

 

 

 

2.5 W [EUR], [EXP]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODULATION

1

Set the preset value of [MOD N] to “100” on the adjustment software.

 

 

 

 

 

 

 

 

BALANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

2

• Channel

: CH 7

Rear

Connect the modulation ana-

Set to square wave

[BAL (Narrow)]

 

• No audio signals applied to the JIG cable.

panel

lyzer with an oscilloscope to the

 

 

 

form

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Set a modulation analyzer as;

 

antenna connector through an

 

 

 

 

 

 

 

 

 

 

 

HPF

: OFF

 

attenuator.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LPF

: 20 kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

De-emphasis

: OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

Detector

: (P–P)/2

 

 

 

 

 

 

 

 

 

 

 

 

 

• Push [P0] while transmitting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FM

1

• Connect an audio generator to the JIG

Rear

Connect the modulation ana-

±2.05 to ±2.15 kHz

DEVIATION

 

cable and set as;

 

panel

lyzer to the antenna connector

 

 

 

 

 

 

 

 

 

 

 

Frequency

: 1.0 kHz

 

through an attenuator.

 

 

 

 

 

 

 

 

 

 

 

Level

: 40 mV rms

 

 

 

 

 

 

 

 

 

 

Set the modulation analyzer to the same condition as “MODULATION BALANCE.”

Transmitting

(NARROW)

 

• Channel

: CH 8

 

 

 

[MOD N C]

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[MOD N L]

2

• Channel

: CH 9

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[MOD N H]

3

• Channel

: CH 10

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(WIDE)

4

• Channel

: CH 4

 

 

±4.05 to ±4.15 kHz

[MOD W C]

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[MOD W L]

5

• Channel

: CH 3

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[MOD W H]

6

• Channel

: CH 2

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(MIDDLE)*

7

• Channel

: CH 11

 

 

±3.15 to ±3.25 kHz

[MOD W C]

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

[MOD M L]

8

• Channel

: CH 12

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

[MOD M H]

9

• Channel

: CH 13

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

DIGITAL

1

Set the preset value of [Digital Mode] to “7” on the adjustment software.

 

DAVIATION

 

 

 

 

 

 

2

• Attach the UT-119 to J2.

Rear

Connect the modulation ana-

±1.41 to ±1.45 kHz

[MOD D C]

 

(Refer to page 4-2 for the installation)

panel

lyzer to the antenna connector

 

 

 

 

 

 

 

 

 

 

 

 

• Channel

: CH 14

 

through an attenuator.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

[MOD D L]

3

• Channel

: CH 15

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

[MOD D H]

4

• Channel

: CH 16

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CTCSS/DTCS

1

• Channel

: CH 17

Rear

Connect a modulation analyzer to

±0.68 to ±0.72 kHz

DEVIATION

 

• No audio signals applied to the JIG cable.

panel

the antenna connector through

 

[CTCS/DTCS]

 

• Set the modulation analyzer to the same

 

an attenuator.

 

 

 

 

 

 

condition as “MODULATION BALANCE.”

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

2TONE,

1

• Channel

: CH 18

Rear

Connect a modulation analyzer to

±1.50 kHz

5TONE,

 

• Transmitting

 

panel

the antenna connector through

 

DTMF

 

 

 

 

an attenuator.

 

[S.Tone]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*; [EUR] only.

 

 

 

 

 

 

6 - 5

Page 18
Image 18
Icom IC-F5063, IC-F5062, IC-F5061 manual Transmit Adjustment, Power