6-4 RECEIVE ADJUSTMENT

Select an adjustment item using [] / [] keys, then set to the specified value using [] / [] keys on the connected PC’s keyboard.

ADJUSTMENT

ADJUSTMENT CONDITION

UNIT

LOCATION

VALUE

RECEIVE

NOTE: “RECEIVE SENSITIVITY” must be adjusted before “S-METER.” Otherwise, “S-METER” will not be

SENSITIVITY

 

adjusted properly.

 

 

 

[BPF (T1) C]

 

 

 

 

 

 

1

• Channel

: CH 3

SP jack

Connect the SINAD meter

Minimum distortion

[BPF (T2) C]

 

• Connect the SSG to the antenna connec-

 

with an 4 load to the SP

level

 

 

 

 

 

tor and set as;

 

 

jack.

 

 

 

Frequency

: 136.000 MHz

 

 

 

 

 

Level

: +20 dBµ(–87 dBm)

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

Deviation

: ±3.5 kHz

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

CONVENIENT:

 

 

 

 

The “RECEIVE SENSITIVITY” can be adjusted automatically.

1:Put the cursor on “[BPF C ALL]” and push [ENTER] key.

2:The connected PC tunes BPF’s to peak levels automaticaly.

S-METER

1

• Channel

: CH 3

Push the [ENTER] key on the connected PC’s keyboard to set

(S3 level)

 

• Connect the SSG to the antenna connec-

“S3” level.

 

 

[RSSI]

 

tor and set as;

 

 

 

 

 

 

 

Frequency

: 136.000 MHz

 

 

 

 

 

 

Level

: +23 dBµ(–84 dBm)

 

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

Deviation

: ±3.5 kHz

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

(S1 level)

2

• Set the SSG as;

: –7 dBµ(–114 dBm)

Push the [ENTER] key again to set “S1” level.

 

 

Level

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

SQUELCH

1

• Channel

: CH 3

External

 

Connect an 4 speaker to

Close the squelch by

[SQL]

 

• Close the squelch by adjusting the value of

speaker

 

the SP jack.

increase the value of

 

 

[SQL] item on the CS-F5060 ADJ’s screen.

 

 

 

[SQL].

 

 

• Connect the SSG to the antenna connec-

 

 

 

Set the [SQL] to the

 

 

tor and set as;

 

 

 

 

value that the audio

 

 

Frequency

: 136.000 MHz

 

 

 

signals just appear.

 

 

Level

: –14 dBµ(–121 dBm)

 

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

Deviation

: ±3.5 kHz

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

†; The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.

6 - 6

Page 19
Image 19
Icom IC-F5062, IC-F5063, IC-F5061 manual Receive Adjustment, Convenient, Adjustment Adjustment Condition Unit Location Value