Burner and nozzle characteristics

Table 1

 

 

 

 

 

Liquid Gas

 

 

 

Natural Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Diameter

Thermal Power

By-Pass

Nozzle

Flow*

Nozzle

 

Flow*

Nozzle

 

Flow*

 

(mm)

kW (p.c.s.*)

1/100

1/100

g/h

 

1/100

 

l/h

1/100

 

l/h

 

 

Nominal

 

Reduced

(mm)

(mm)

***

 

**

(mm)

 

 

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fast

100

3.00

 

0.7

41

87

218

 

214

128

 

286

143

 

286

(Large)(R)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi Fast

75

1.90

 

0.4

30

70

138

 

136

104

 

181

118

 

181

(Medium)(S)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

51

1.00

 

0.4

30

52

73

 

71

76

 

95

80

 

95

(Small)(A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Oven

-

2.00

 

1.0

48-49

68

145

 

143

107

 

190

114

 

183

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply

Nominal (mbar)

 

 

28-30

 

37

20

 

13

 

Minimum (mbar)

 

 

20

 

25

17

 

6,5

 

Pressures

 

 

 

 

 

Maximum (mbar)

 

 

35

 

45

25

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*At 15°C and 1013 mbar- dry gas

**

Propane

P.C.S. = 50,37 MJ/Kg

***

Butane

P.C.S. = 49,47 MJ/Kg

 

Natural

P.C.S. = 37,78 MJ/m3

S S

A R

K1G2/R K 1G20/R

7

Page 7
Image 7
Indesit K1G20/R, K1G2/R manual Burner and nozzle characteristics, Liquid Gas Natural Gas, 1G2/R K 1G20/R