Technical characteristics

Electrical connection

The electrical safety of this appliance can only be guaranteed if the latter is correctly and efficiently earthed, in compliance with regulations on electrical safety. Always ensure that this vital safety measure has been taken. If you have any doubts, call in a qualified technician to check the electrical system thoroughly.

The manufacturer denies all responsibility for dam- age resulting from a system which has not been earthed correctly.

Before powering the appliance, check whether the technical characteristics featured on the appliance data plate correspond with those of the mains electrical sys- tem.

Check that the current load of the mains supply and of the power sockets is suitable for the maximum power of the appliance, indicated on the appliance data plate. If in doubt, contact a qualified professional.

Disconnect the appliance from the electricity supply before all operations.

You may connect your hob to the electrical system in two different ways:

by means of ajunction box: if the appliance is connected permanently to the mains, an omnipolar circuit breaker, accessible if necessary, with a mini- mum contact opening of 3 mm should be installed.

by means of a socket conforming to the regulations in force in the country where the appliance is fitted. It should be accessible whenever necessary; do not use adaptors, multiple plugs or extensions.

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

Fuses

Fuses

 

 

 

 

Electrical connections

 

 

Sections

 

 

 

 

 

 

Frequency

Sections

 

 

 

 

 

 

 

 

 

 

 

 

 

KBT 6323 IO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

4

3

2

1

FR-AT-BE-DE-GP--

 

 

ES-IE-IL-IS-IT-LU-

25 A*

32 A

 

 

 

 

 

 

 

 

 

 

 

 

 

RE-FI-GB-GR-PT--

 

 

 

 

N

 

 

 

 

 

L

SE-MA-NZ

2.5 mm²

4 mm²

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230V-1+N~50 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

4

3

2

1

FR-BE-NO

25 A*

32 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.5 mm²

4 mm²

 

 

 

 

L2

 

 

 

 

 

L1

230V-2~50 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

4

3

2

1

FR-BE-CH-DE-AT--

 

 

ES-IL-IT-NZ-PT-

16 A*

16 A*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

L2

L1

MA- LU-SE-IS-NL

1.5 mm²

1.5 mm²

 

 

 

 

 

 

 

 

 

 

 

 

 

400V2-N~50 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

4

3

2

1

FR-BE-NO

16 A*

16 A*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230V3~50 Hz

1.5 mm²

1.5 mm²

 

 

 

 

L3

 

 

 

L2

L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

4

3

2

1

NL

16 A*

16 A*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230V2+2-N~50 Hz

1.5 mm²

1.5 mm²

 

 

 

 

N2

N1

 

L2

L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

4

3

2

1

CY-AU-NZ-KW-MT

25 A*

32 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

240V-1+N~50 Hz

2.5 mm²

4 mm²

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Application of the simultaneity coefficient in accordance with IEC 60335-2-6

norm

In the event of an incorrect connection:

if your appliance does not work,

if the right-hand zones (KBT6323 IO: the back right and front zones) are inaccessible and the power dis- plays blink,

check the position of the wires in the terminal board,

check that all screws are tight,

check the positioning of the jumpers.

Important

After connecting the appliance to the flexible cable, tighten all the screws on the terminal board. Make sure jumpers are installed according to the type of mains system as indicated in the table.

For example: line 1 in the table

2

 

4

1

3

5

Jumpe

Phase

Neutral

Earth

 

(brown)

(blue)

(green/yellow)

This appliance conforms with the following European Community Directives:

-73/23/EEC of 19/02/73 (Low Voltage) and subsequent amendments;

-89/336/EEC of 03/05/89 (Electromagnetic compatibility) and subsequent amendments;

-93/68/EEC of 22/07/93 and subsequent amendments;

Warning: If the hob is fitted above a built-in oven, the hob and the oven must be connected to the mains separately for safety reasons and to simplify operations when it is necessary to pull the oven out for some reason.

Page 23
Image 23
Indesit mk 64 r manual Technical characteristics, Electrical connection

mk 64 r specifications

The Indesit MK 64 R is a remarkable built-in gas cooktop designed to elevate your cooking experience. Featuring a sleek and modern design, this appliance seamlessly integrates into any kitchen style, making it a popular choice for both amateur and professional chefs. Its efficient configuration allows for ease of use, allowing you to prepare meals with precision and flair.

One of the standout features of the Indesit MK 64 R is its four powerful gas burners. These burners vary in size, accommodating different cooking needs, from simmering delicate sauces to boiling pasta quickly. The burners are designed for rapid heating, ensuring you save time during meal preparation. The presence of double flame burners offers intense heat for high-temperature cooking, while the smaller burners provide a gentler flame for more intricate dishes.

The MK 64 R incorporates the innovative Flame Failure Safety Device, ensuring peace of mind while cooking. This technology automatically cuts off the gas supply if the flame extinguishes, providing an added layer of safety for families and busy chefs alike. Furthermore, the easy-to-use rotary knobs are positioned conveniently on the front panel, allowing for optimal control over flame intensity.

Another essential characteristic of this cooktop is its enamelled cast-iron pan supports, which provide excellent stability and support for pots and pans of varying sizes. This robust design not only enhances durability but also ensures even heat distribution for consistent cooking results. The panel's sleek design makes it easy to clean, with a smooth surface that prevents food particles from getting stuck.

The Indesit MK 64 R operates on natural gas but can be converted for use with LPG, providing flexibility for different home setups. Its energy efficiency ratings also make it an environmentally-friendly choice, helping to reduce energy consumption without sacrificing performance.

In summary, the Indesit MK 64 R gas cooktop combines modern design with functionality and safety. Its powerful burners, intuitive controls, and robust construction make it a valuable addition to any kitchen, catering to a wide range of cooking tasks from everyday meals to gourmet creations. Whether you are a novice cook or a seasoned chef, this versatile cooktop is sure to enhance your culinary skills and inspire creativity in the kitchen.