InFocus IN8606HD manual Function, Command, Default, Step, Parameter, 4000

Models: IN8606HD

1 62
Download 62 pages 28.02 Kb
Page 60
Image 60
4000

IN8606HD User’s Manual

No

Function

Command

RW

Min

Max

Default

Step

Parameter

 

 

 

 

 

 

 

 

Valid only when Display

 

 

 

 

 

 

Source

 

Mode = User

16V

Color Temp

TMP

RW

0

2

1

0:Warm

Specific

 

 

 

 

 

 

 

1:Normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2:Cold

17V

Contrast

CON

RW

0

100

50

1

Valid only when Display

Mode = User

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0:VGA1

 

 

 

 

 

 

 

 

5:HDMI-1

18V

Current Source

SRC

RW

0

13

0

1

6:HDMI-2

10:Component

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12:Video

 

 

 

 

 

 

 

 

13:S-Video

21V

Digital Zoom

DZM

RW

-10

10

0

1

-10~10

 

 

 

 

 

 

 

 

0:No error

 

 

 

 

 

 

 

 

1:Lamp not lit after 5 At-

 

 

 

 

 

 

 

 

tempts

 

 

 

 

 

 

 

 

3:Lamp went out unexpect-

27V

Error Condition

ERR

R

n/a

n/a

n/a

n/a

edly

 

 

 

 

 

 

 

 

4:Fan failure

 

 

 

 

 

 

 

 

5:Over- heating

 

 

 

 

 

 

 

 

8:DMD error

 

 

 

 

 

 

 

 

9:Color wheel

28V

Factory Reset

RST

W

n/a

1

1

1

1:reset

32V

Freeze Screen

FRZ

RW

0

1

0

1

0:Disable

 

 

 

 

 

 

 

 

Valid only when Display

 

 

 

 

 

 

 

 

Mode = User

 

 

 

 

 

 

 

 

0:1.8

34V

Gamma

GTB

RW

0

5

Source

1

1:2.0

Specific

2:2.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3:2.4

 

 

 

 

 

 

 

 

4:B&W

 

 

 

 

 

 

 

 

5:Linear

40V

Horz. Position

HPS

RW

x

x

0

1

RGB source only

(HPS?) to get range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Displays the number of

45V

Lamp Hours in High

LMO

R

0

9999

 

 

hours that the current lamp

Power Mode

 

 

has run in High Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Normal) mode.

 

 

 

 

 

 

 

 

Displays the number of

46V

Lamp Hours in Low

LME

R

0

9999

 

 

hours that the current lamp

Power Mode

 

 

has run in Low Power (Eco)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mode.

47V

Lamp Life

LIF

R

n/a

4000

 

 

240W lamp life 4000

49V

Lamp Resets (Total

LMR

R

0

9999

0

1

 

number)

 

 

 

 

 

 

 

 

 

62V

Lamp Low Power

IPM

RW

0

1

0

1

1=ECO, 0=Normal

53