Page 25INF55WIN8 Hardware Guide
Advanced Option
Sel Adjust Enter Back Quit

< >

<

<

ADVANCED OPTION
INPUT RESOLUTION
BLACK LEVEL EXPANSION
GAMMA SELECTION
SCAN MODE
SCAN CONVERSION
FILM MODE
IR CONTROL
KEYBOARD CONTROL
TILING
HEAT STATUS
DATE AND TIME
SCHEDULE
MONITOR ID
DDC/CI
ADVANCED OPTION RESET
MIDDLE
2.2
UNDER SCAN
PROGRESSIVE
AUTO
ON
InputResoluon: sets the resoluon of the VGA input. This is only required when the monitor is unable to detect the VGA input
resoluon correctly. Opons include: 1024 x 768, 1280 x 768, 1360 x 768, 1366 x 768, 640 x 480, 720 x 480, 852 x 480, 800 x 600,
1064 x 600, 720 x 576, 1400 x1050, 1680 x 1050, 720 x 400, 640 x 400, 1440 x 900, 1600 x 900 and Auto.
Black Level Expansion: reveals addional details in black/dark areas of video inputs. Opons include: Low, Middle, High and O
(default).
GammaSelecon:adjusts the gamma value of the image and opmizes image brightness and contrast. Opons include: Nave, 2.2
(default), 2.4 and S Gamma.
Scan Mode: removes noise around the edges of a video image. Opons include: Under scan (default for VGA sources) and Over scan
(default for video sources).
Scan Conversion: adjusts the conversion of source images. Opons include: Interlace and Progressive (recommended).
Film Mode: controls lm mode detecon and determines whether the original source of the input video was lm or video. Opons
include: Auto (default) and O.
IR Control: disables and enables the IR sensor on the monitor. Opons include: Normal (default; IR is enabled) and Lock (IR is dis-
abled).
Keyboard Control: disables and enables the keypad on the right-hand side of the monitor. Opons include: Lock (keypad is disabled)
and Unlock (default; keypad is enabled).
Tiling: This feature only supported in Monitor Mode.
Heat Status: displays the current internal temperature of the monitor (+/-5°) and the cooling fan sengs. To change the fan sengs,
go to the Conguraon 1 menu and choose the Screen Saving opon.
Date and Time: lists the current date and me informaon of the monitor's internal clock and allows the user to make date and me
adjustments. Opons include: Year, Month, Day, Hour, Minute, Daylight Saving Time.
Schedule: (Supported in Monitor Mode only) enables the user to create up to seven disnct on/o schedules for the monitor. For
each schedule, the user oponally selects the me the monitor should turn on and o, which input source is automacally acvated
(if desired) and what day(s) this occurs.
Monitor ID: set the idencaon number of the monitor via the RS232C connecon. Each monitor must have a unique idencaon
number when mulple monitors are connected. Range: 1-26. (Default; 1)
DDC/CI: enables and disables DDC/CI communicaon. Opons include: On (default) and O.
AdvancedOponReset: resets all Advanced Opon menu items to factory default sengs. Opons: Yes and No.