5
INSTALLING FILTRATION SYSTEM
A
Personal Injury: Do not locate filter above an outlet or other electrical device. Install head and bracket so that connections require no stretching, kinking or pinching of tubing.
QMark hole locations for filter head and bracket in a spot that allows for filter replacement.
QDrill 1/8" starter holes and attach bracket to wall with wood screws, turning until snug.
QRemove red filter cap, insert filter cartridge into filter head and twist clockwise until “LOCK” arrow on the filter aligns with arrow on bracket.
B
from water | to dispenser |
supply line |
|
|
|
|
|
|
|
Property Damage: Tube runs need to form to the cabinet’s contours to allow storage space with no sharp bends. Tubes need clean, perpendicular,
QDetermine length of tubing required, then cut to length making sure the cut is perpendicular and
QInsert a white 3/8" tube into inlet side of filter head until it stops.
Press in again to ensure a secure fit.
QInsert the other white 3/8" tube into outlet side of filter head until it stops. Press in again to ensure a secure fit.
C Hot & cool models
From filter or
water supply line
Hot only models
Plug
From filter or
water supply line
Q Insert the copper tube(s) from the |
dispenser into the 3/8" to 1/4" |
Q Connect the white 3/8" tube |
from the right outlet on the filter |
head into the |
until it stops. Press in again to |
ensure a secure fit. |
Property Damage: Do not extend the copper
lines farther than the 16" provided.
To remove tube(s) or plug from |
depress the release ring and gently pull away. |
D
Discharge
tube
From water | To dispenser |
supply line |
|
It is normal for approximately 2 oz. of water to
discharge when filter is removed.
QTo redirect filter replacement water discharge, place 6" clear tube over vent hole on the left side of filter head.
QNote: 3/8" fitting is required to make connection to water supply.
QConnect remaining white 3/8" tube to incoming water supply line.
(See Step 6.)
9