3
MOUNTING THE TANK
A
Tank must be mounted level to ensure proper operation.
Property Damage: Tank must be located within 16" of faucet and within 30" or less of a standard grounded outlet. DO NOT extend plumbing or electrical lines.
■Select a spot under the sink to mount tank vertically within reach of both plumbing and electrical connections. The tank should be within 16" or less of faucet water lines and within 30" or less of a standard grounded outlet.
■While holding tank in place on
the spot selected for installation, use a pencil to mark locations for 2 hanging screws.
B
Leave 1/4" for hanging tank.
Mount tank vertically in an area that
allows clearance on the underside of the
tank for drainage, if necessary. DO NOT over tighten screws.
Screws provided are for use in wood studs or cabinets only. Use wall anchors (not supplied) for installation into drywall.
■
■Turn screws into
■Hang the tank on the screws.
■Tighten the screws with only 1/2 turn clockwise.
CONNECTING FAUCET TO TANK | ||
4 A |
| ■ Without depressing the gray button, |
|
| place the |
|
| the end of the blue 1/4" tube onto |
|
| the left plastic fitting on the tank, |
|
| pushing until it clicks into place. (1) |
1 | 2 |
|
|
| ■ Slip the flexible white 7/16" tube |
Property Damage: Pinched or blocked water lines | over barbed middle fitting and slide | |
down approximately 1/2". (2) |
may cause damage to the dispenser tank.
B
3
Property Damage: Check to make sure tubes are connected properly and are pushed in as far as possible.
■Slip the clear 5/16" tube over the far right smooth fitting and slide down approximately 1/2". (3)
■Visually check for pinched or crimped tubes.
6