Hardware Installation

2.5Configurable Disk Drive SCSI Parameters

When a SCSI hard disk drive is initialized the first time by the RAID controller, its SCSI parameters are automatically set to their optimal settings. Most settings are set automatically and can not be configured manually. To view or configure disk drive SCSI parameters from the Storage Console, choose Advanced Setup Æ Configure Physical Devices Æ Select Physical Drive Æ SCSI Parameter/Initialize.

Table 2-1. Configurable Disk Drive SCSI Parameters

Parameter

Setting/

Configuration

Description

Value

 

 

 

 

 

 

 

Synch.

Enabled /

Automatic

This setting when enabled allows the controller to

Transfer

Disabled

operate in synchronous transfer mode

 

 

 

 

 

 

 

 

Allows for the setting of the speed for the SCSI

Synch.

Speed

 

hard disks (up to 320 MB/sec for U320 drives).

Automatic

No matter the setting, the SCSI bus will negotiate

Transfer Rate

(MB/sec)

the fastest speed up to this setting. Lowering the

 

 

 

 

setting will force the disk drive to transfer at the

 

 

 

lower speed.

 

 

 

 

 

Enabled /

 

Enabling this setting allows for the disk drive to

Disconnect

Automatic

disconnect from the SCSI bus when it’s not

Disabled

participating in a transfer. This allows for optimal

 

 

 

 

 

bus utilization by all devices on the bus.

 

 

 

 

Tagged

 

 

When enabled, this feature allows the SCSI disk

On / Off

Automatic

drive to execute more than one command at a

Queues

 

 

time.

 

 

 

 

 

 

 

Disk Read

 

 

For performance reasons, the Read Ahead and

and Write

On / Off

Configurable

Write cache of the hard disk drives should always

Cache

 

 

be on. This is the default setting.

 

 

 

 

2.6Configurable I/O Controller SCSI Parameters

When the controller starts up, its SCSI parameters are automatically set to their optimal settings. Manual configuration is not required. However, you can customize I/O SCSI parameters for each channel on the controller by using the Storage Console menu Advanced Setup > Configure Controller > Controller Settings.

Table 2-2. Configurable I/O Controller SCSI Parameters

Parameter

Setting/Value

Description

 

 

 

 

 

When this is set to On, Domain validation allows for a

 

 

cyclical check of the correct data transfer at a given rate for

 

 

the respective channel.

Domain Validation

On / Off

For ultra320, the SRCMRU controller supports Basic,

 

 

Enhanced, and Margined Domain Validation. For ultra160,

 

 

the SRCMRU controller supports Basic and Enhanced

 

 

Domain Validation.

 

 

 

16