RAID firmware limits the controller to a maximum of 30 host drives (RAID volumes) per controller. There is a minimum of at least one host drive per array drive. A host drive can only be associated with (or reside on) a single array drive. Like array drives, host drives can reside on hard disk drives that are isolated to a single channel or span both of the channels of the RAID controller.

Table 3-5. RAID Controller Drive Maximum Limitations (SRCMRU)

Drive Type

Maximum

Maximum

Maximum

Maximum

Per Channel

Per Controller

Per Array Drive

Per Host Drive

 

 

 

 

 

 

Physical Disk Drives

15

30

30

30

(2 minimum)

 

 

 

 

 

 

 

 

 

RAID Array Drives

7

15

 

1

 

 

 

 

 

RAID Host Drives

 

30

2

 

 

 

 

 

 

22