3.2.4. Power Limit / Hazardous Energy Levels

ATX12V Power Supply Design Guide

Version 2.0

3.2.4. Power Limit / Hazardous Energy Levels

Under normal or overload conditions, no output shall continuously provide 240 VA under any conditions of load including output short circuit, per the requirement of UL 1950/CSA 950 / EN 60950/IEC 950.

3.2.5. Efficiency

3.2.5.1. General

The power supply required minimum is 70% efficient under “Full” load, 70% under

“typical” load, and 60% in a “light” load or idle condition. The efficiency of the power supply should be tested at nominal input voltage of 115VAC input and/or 230VAC input, under the load conditions defined in Table 7 and Table 8, and under the temperature and operating conditions defined in Section 5. The loading condition for testing efficiency shown in Table 8 represents a fully loaded system, a ~50% (typical) loaded system, and a ~20% (light) loaded system.

Table 7. Minimum Efficiency Vs Load

 

Loading

Full load

Typical load

 

Required Minimum Efficiency

 

 

 

70%

70%

 

 

 

 

 

Recommended Minimum Efficiency

 

 

 

75%

80%

 

 

 

 

Light load

60%

68%