ATX12V Power Supply Design Guide

Version 2.0

5.

Environmental

 

The following subsections define recommended environmental specifications and test

 

parameters, based on the typical conditions to which an ATX12V power supply may be

 

subjected during operation or shipment.

5.1.

Temperature

 

 

Operating ambient

+10 °C to +50 °C

 

 

(At full load, with a maximum temperature rate of change of

 

 

5 °C/10 minutes, but no more than 10 °C/hr.)

 

Non-operating ambient

-40 °C to +70 °C

 

 

(Maximum temperature rate of change of 20 °C/hr.)

5.2.

Thermal Shock (Shipping)

 

Non-operating

-40 °C to +70 °C

 

 

15 °C/min dT/dt 30 °C/min

 

 

Tested for 50 cycles; Duration of exposure to temperature

 

 

extremes for each half cycle shall be 30 minutes.

5.3.

Humidity

 

 

Operating

To 85% relative humidity (non-condensing)

 

Non-operating

To 95% relative humidity (non-condensing)

 

 

Note: 95% RH is achieved with a dry bulb temperature of

 

 

55 °C and a wet bulb temperature of 54 °C.

5.4.

Altitude

 

 

Operating

To 10,000 ft

 

Non-operating

To 50,000 ft