Intel ATX12V manual Second optional fan may go in this location, Air inlet grill, 55% open area

Models: ATX12V

1 43
Download 43 pages 35.98 Kb
Page 29
Image 29
Second optional fan may go in this location

ATX12V Power Supply Design Guide

Version 2.0

.

Second optional fan may go in this location

Air inlet grill, 55% open area.

53 REF

WIRE HARNESS

16 REF

Air inlet grill, 55% open area. 150 REF Manual background

Manual background 20.0 Manual background

4.0X6(2X)

(2X)

Optional air

inlet area.

146.0

140 REF

Optional air inlet area.

Preferred locations of manufacturer label

No. 6-32 UNC-2B THREADED HOLE (4X)

138.0

See Note 4.

86 REF Manual background

Notes; unless otherwise specified:

1.Dimensions are in mm.

2.Drawing is not to scale.

3.Tolerances: X +/- 1 X.X +/- 0.5

4.If a wire grill is required for acoustics or thermals, the grill and screws must be flush mounted.

64.0

16.0

6.0 (2X) Manual background

114.0

74.0

6.0

psu_grills

Figure 8. Power Supply Dimensions for Chassis That Does Not Require Top Venting

29

Page 29