6 Design Considerations

6 Design Considerations

6.1Thermal Management

A heat-spreader plate assembly is available from Kontron Embedded Modules GmbH for the ETX®-CD. The heat-spreader plate on top of this assembly is NOT a heat sink. It works as an ETX®-standard thermal interface to use with a heat sink or other cooling device.

External cooling must be provided to maintain the heat-spreader plate at proper operating temperatures. Under worst-case conditions, the cooling mechanism must maintain an ambient air and heat-spreader plate temperature of 60°C or less.

The aluminum slugs and thermal pads on the underside of the heat-spreader assembly implement thermal interfaces between the heat spreader plate and the major heat-generating components on the ETX®-CD. About 80 percent of the power dissipated within the module is conducted to the heat-spreader plate and can be removed by the cooling solution.

You can use many thermal-management solutions with the heat-spreader plates, including active and passive approaches. The optimum cooling solution varies, depending on the ETX® application and environmental conditions. Please see the ETX® Design Guide for further information on thermal management.

6.2Heatspreader Dimensions

This is the backside view of the heatspreader plate.

Kontron User's Guide ETX CD

41

Page 41
Image 41
Intel ETX CD manual Design Considerations, Thermal Management, Heatspreader Dimensions