Intel GS-SR195V Com PortAddress, Baud Rate, Console Type, FlowControl, Continue C.R. after POST

Models: GS-SR195V

1 56
Download 56 pages 11.75 Kb
Page 49
Image 49
Com PortAddress

BIOS Setup

Com PortAddress

If this option is set to enabled, it will use a port on the motherboard.

On-board COMA

Use COMA as he COM port address.

On-board COMB

Use COMB as he COM port address.

Disabled

Disable this function. (Default value)

Baud Rate

This option allows user to set the specified baud rate.

Options

300, 1200, 2400, 9600, 19.2K, 38.4K, 57.6K, 115.2K.

Console Type

This option allows user to select the specified console type. This is defined by IEEE. PC-ANSI is the standard PC-type terminal. Note that for VT100+, you must select English as your languuage. And VT-UTF8 uses unicode.

Options

vt100, vt100+, vt100 8bit, PC ANSI 7bit, PC-ANSI, VT-UTF8.

FlowControl

Enables Flow Control when EMP is dahring the same serial port as console redirection, the flow control must be set to CTS/RTS or CTS/RTS+CD depending on whether a modem is used.

None

Not supported.

XON/OFF

Software control.

CTS/RTS

Hardware control. (Default values)

Continue C.R. after POST

This option allows user to enable console redirection after O.S has loaded.

On

Enable console redirection after O.S has loaded.

Off

Disable this function. (Default value)

4 9

Page 49
Image 49
Intel GS-SR195V manual Com PortAddress, Baud Rate, Console Type, FlowControl, Continue C.R. after POST