BMC Force
Update Mode
2
3
J1D2
| Disable | |
Password | 2 | |
Enable | ||
Reset | ||
3 | ||
| ||
| J1D1 |
2
3
J1D3
Clear
CMOS
TP02080
Figure 9. Clear Password Jumper
4.Wait five seconds.
5.Return the Password Clear jumper to the Password Clear Protect position, covering pins 1 and 2.
6.Close the server chassis.
7.Reconnect the AC power and power up the server.
8.The password is now cleared and can be reset by going into BIOS setup.
Clearing the CMOS
If you are not able to access the BIOS setup screens, the CMOS Clear jumper will need to be used to reset the configuration RAM.
1.Power down the system and disconnect the AC power.
2.Open the server.
3.Move the jumper from the normal operation position, CMOS Clear by BMC, at pins 1 and 2 to the CMOS Clear Force Erase position, covering pins 2 and 3.
Intel® Server Board S5000PAL User’s Guide | 19 |