BMC Force

Update Mode

2

3

J1D2

 

Disable

Password

2

Enable

Reset

3

 

 

J1D1

2

3

J1D3

Clear

CMOS

TP02080

Figure 10. Clear CMOS Jumper

4.Wait five seconds.

5.Return the CMOS Clear jumper to the CMOS Clear by BMC location, covering pins 1 and 2.

6.Close the server chassis.

7.Reconnect the AC power and power up the system.

8.The CMOS is now cleared and can be reset by going into the BIOS setup.

20

Intel® Server Board S5000PAL User’s Guide

Page 38
Image 38
Intel S5000PAL manual Clear Cmos Jumper