IPSO CHM2097N installation manual Electrical Installation Requirements Model IWF030 2-speed

Models: CHM2097N

1 75
Download 75 pages 48.88 Kb
Page 19
Image 19

Washer-Extractors

WARNING

Only trained personnel should perform this procedure. Use caution while servicing machines with covers removed and power applied.

W700

Electrical Installation Requirements - Model IWF030 (2-speed)

 

 

 

 

 

Boiler Fed/Steam Heat

 

Electric Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code

Voltage

Cycle

Phase

Wire

FullLoad Amps

 

Recommended CircuitBreaker (US-market)

2

kWStandard HeatingElements

FullLoad Amps

 

Recommended CircuitBreaker (US-market)

2

 

 

 

 

 

 

 

 

 

AWG/mm

 

 

 

 

 

AWG/mm

 

 

 

 

 

 

US

 

NON-US

 

 

 

US

 

NON-US

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

440-480

50/60

3

3+PE

1

10

 

6

14/2.5

 

19.8

25

 

20

14/2.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

380-415

50/60

3

3+N+PE

1

10

 

6

14/2.5

6x2 kW

22.8

30

 

25

14/2.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

200-240

50/60

3

3+PE

2.5

10

 

6

14/2.5

35.3

40

 

40

12/4.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

200-240

50/60

1/3

2/3+PE

2.5

10

 

6

14/2.5

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alternative Electric Heat Options

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

440-480

50/60

3

3+PE

 

 

 

 

 

 

24.5

30

 

25

14/2.5

 

 

 

 

 

 

 

 

 

 

3x3 kW

 

 

 

 

 

P

380-415

50/60

3

3+N+PE

 

 

 

 

 

28.2

40

 

32

12/2.5

 

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

Q

200-240

50/60

3

3+PE

 

 

 

 

 

43.5

40

 

50

12/4.0

 

 

 

 

 

3x2 kW

 

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

440-480

50/60

3

3+PE

 

 

 

 

 

 

29.2

40

 

32

12/4.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

380-415

50/60

3

3+N+PE

 

 

 

 

 

6x3 kW

33.7

40

 

40

12/4.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

200-240

50/60

3

3+PE

 

 

 

 

 

51.8

50

 

63

10/6.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 4

5-08-51

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

18

Page 19
Image 19