Electrical Installation Requirements - Model IWF018 (M-speed)
|
|
|
|
| Boiler Fed/Steam Heat |
| Electric Heat |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Code | Voltage | Cycle | Phase | Wire | FullLoad Amps |
| Recommended CircuitBreaker | 2 | kWStandard HeatingElements | FullLoad Amps |
| Recommended CircuitBreaker | 2 | ||
|
|
|
|
|
|
|
|
| AWG/mm |
|
|
|
|
| AWG/mm |
|
|
|
|
|
| US |
|
|
|
| US |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N | 50/60 | 3 | 3+PE | 3 | 10 |
| 10 | 14/2.5 |
| N/A | N/A |
| N/A | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P | 50/60 | 3 | 3+N+PE | 7 | 15 |
| 16 | 14/2.5 | 3x2 kW | 16 | 20 |
| 20 | 12/4.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Q | 50/60 | 3 | 3+PE | 7 | 15 |
| 16 | 14/2.5 | 23 | 30 |
| 32 | 10/6.0 | ||
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X | 50/60 | 1/3 | 2/3+PE | 7 | 15 |
| 16 | 14/2.5 |
| N/A | N/A |
| N/A | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Alternative Electric Heat Options | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N | 50/60 | 3 | 3+PE |
|
|
|
|
|
| N/A | N/A |
| N/A | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P | 50/60 | 3 | 3+N+PE |
|
|
|
|
| 3x1.4 kW | 13 | 15 |
| 16 | 14/2.5 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Q | 50/60 | 3 | 3+PE |
|
|
|
|
| 18 | 20 |
| 20 | 12/4.0 | ||
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X | 50/60 | 1/3 | 2/3+PE |
|
|
|
|
|
| N/A | N/A |
| N/A | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N | 50/60 | 3 | 3+PE |
|
|
|
|
|
| N/A | N/A |
| N/A | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P | 50/60 | 3 | 3+N+PE |
|
|
|
|
| 3x3 kW | 21 | 30 |
| 32 | 10/6.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Q | 50/60 | 3 | 3+PE |
|
|
|
|
| 30 | 40 |
| 40 | 8/10.0 | ||
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X | 50/60 | 1/3 | 2/3+PE |
|
|
|
|
|
| N/A | N/A |
| N/A | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N | 50/60 | 3 | 3+PE |
|
|
|
|
|
| 20 | 30 |
| 25 | 10/6.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P | 50/60 | 3 | 3+N+PE |
|
|
|
|
| 3x4 kW | 24 | 30 |
| 30 | 10/6.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Q | 50/60 | 3 | 3+PE |
|
|
|
|
| N/A | N/A |
| N/A | N/A | ||
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X | 50/60 | 1/3 | 2/3+PE |
|
|
|
|
|
| N/A | N/A |
| N/A | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Table 10