WARNING
Only trained personnel should perform this procedure. Use caution while servicing machines with covers removed and power applied.
W700
Electrical Installation Requirements - Model IWF033 (M-speed)
|
|
|
|
| Boiler Fed/Steam Heat |
| Electric Heat |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Code | Voltage | Cycle | Phase | Wire | FullLoad Amps |
| Recommended CircuitBreaker | 2 | kWStandard HeatingElements | FullLoad Amps |
| Recommended CircuitBreaker | 2 | ||
|
|
|
|
|
|
|
|
| AWG/mm |
|
|
|
|
| AWG/mm |
|
|
|
|
|
| US |
|
|
|
| US |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N | 50/60 | 3 | 3+PE | 4 | 10 |
| 10 | 14/2.5 |
| 30 | 40 |
| 40 | 8/10.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P | 50/60 | 3 | 3+N+PE | 12 | 15 |
| 16 | 14/2.5 | 6x3 kW | 38 | 50 |
| 50 | 8/10.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Q | 50/60 | 3 | 3+PE | 12 | 15 |
| 16 | 14/2.5 | 57 | 70 |
| 70 | 4/25.0 | ||
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X | 50/60 | 1/3 | 2/3+PE | 12 | 15 |
| 16 | 14/2.5 |
| N/A | N/A |
| N/A | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Alternative Electric Heat Options | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N | 50/60 | 3 | 3+PE |
|
|
|
|
|
| 26 | 30 |
| 30 | 10/6.0 | |
|
|
|
|
|
|
|
|
|
| 3x3 kW |
|
|
|
|
|
P | 50/60 | 3 | 3+N+PE |
|
|
|
|
| 34 | 40 |
| 40 | 8/10.0 | ||
|
|
|
|
|
|
|
|
|
| + |
|
|
|
|
|
Q | 50/60 | 3 | 3+PE |
|
|
|
|
| 50 | 60 |
| 60 | 6/16.0 | ||
|
|
|
|
| 3x2 kW |
| |||||||||
X | 50/60 | 1/3 | 2/3+PE |
|
|
|
|
|
| N/A | N/A |
| N/A | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N | 50/60 | 3 | 3+PE |
|
|
|
|
|
| 34 | 40 |
| 40 | 8/10.0 | |
|
|
|
|
|
|
|
|
|
| 3x3 kW |
|
|
|
|
|
P | 50/60 | 3 | 3+N+PE |
|
|
|
|
| 53 | 60 |
| 60 | 6/16.0 | ||
|
|
|
|
|
|
|
|
|
| + |
|
|
|
|
|
Q | 50/60 | 3 | 3+PE |
|
|
|
|
| N/A | N/A |
| N/A | N/A | ||
|
|
|
|
| 3x4 kW |
| |||||||||
X | 50/60 | 1/3 | 2/3+PE |
|
|
|
|
|
| N/A | N/A |
| N/A | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N | 50/60 | 3 | 3+PE |
|
|
|
|
|
| 21 | 30 |
| 30 | 10/6.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P | 50/60 | 3 | 3+N+PE |
|
|
|
|
| 6x2 kW | 30 | 40 |
| 40 | 8/10.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Q | 50/60 | 3 | 3+PE |
|
|
|
|
| 42 | 50 |
| 50 | 8/10.0 | ||
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X | 50/60 | 1/3 | 2/3+PE |
|
|
|
|
|
| N/A | N/A |
| N/A | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N | 50/60 | 3 | 3+PE |
|
|
|
|
|
| 39 | 50 |
| 50 | 8/10.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P | 50/60 | 3 | 3+N+PE |
|
|
|
|
| 6x4 kW | 47 | 60 |
| 60 | 6/16.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Q | 50/60 | 3 | 3+PE |
|
|
|
|
| N/A | N/A |
| N/A | N/A | ||
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X | 50/60 | 1/3 | 2/3+PE |
|
|
|
|
|
| N/A | N/A |
| N/A | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Table 13
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 60 |