Washer-Extractors

WARNING

Only trained personnel should perform this procedure. Use caution while servicing machines with covers removed and power applied.

W700

Electrical Installation Requirements - Model IWF055 (M-speed)

 

 

 

 

 

Boiler Fed/Steam Heat

 

Electric Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code

Voltage

Cycle

Phase

Wire

FullLoad Amps

 

Recommended CircuitBreaker (US-market)

2

kWStandard HeatingElements

FullLoad Amps

 

Recommended CircuitBreaker (US-market)

2

 

 

 

 

 

 

 

 

 

AWG/mm

 

 

 

 

 

AWG/mm

 

 

 

 

 

 

US

 

NON-US

 

 

 

US

 

NON-US

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

440-480

50/60

3

3+PE

6

15

 

10

14/2.5

 

32

40

 

40

8/10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

380-415

50/60

3

3+N+PE

16

20

 

20

12/4.0

6x3 kW

43

50

 

50

8/10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

200-240

50/60

3

3+PE

16

20

 

20

12/4.0

62

70

 

70

4/25.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

200-240

50/60

1/3

2/3+PE

16

20

 

20

12/4.0

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alternative Electric Heat Options

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

440-480

50/60

3

3+PE

 

 

 

 

 

 

27

30

 

32

10/6.0

 

 

 

 

 

 

 

 

 

 

3x3 kW

 

 

 

 

 

P

380-415

50/60

3

3+N+PE

 

 

 

 

 

40

50

 

50

8/10.0

 

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

Q

200-240

50/60

3

3+PE

 

 

 

 

 

56

60

 

60

6/16.0

 

 

 

 

 

3x2 kW

 

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

440-480

50/60

3

3+PE

 

 

 

 

 

 

36

40

 

40

8/10.0

 

 

 

 

 

 

 

 

 

 

3x3 kW

 

 

 

 

 

P

380-415

50/60

3

3+N+PE

 

 

 

 

 

48

50

 

50

8/10.0

 

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

Q

200-240

50/60

3

3+PE

 

 

 

 

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

3x4 kW

 

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

440-480

50/60

3

3+PE

 

 

 

 

 

 

23

30

 

25

10/6.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

380-415

50/60

3

3+N+PE

 

 

 

 

 

6x2 kW

35

40

 

40

8/10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

200-240

50/60

3

3+PE

 

 

 

 

 

48

50

 

50

8/10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

440-480

50/60

3

3+PE

 

 

 

 

 

 

40

50

 

50

8/10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

380-415

50/60

3

3+N+PE

 

 

 

 

 

6x4 kW

53

60

 

60

8/10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

200-240

50/60

3

3+PE

 

 

 

 

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 15

5-08-51

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

68

Page 69
Image 69
IPSO CHM2097N installation manual Electrical Installation Requirements Model IWF055 M-speed