Jackson AJ-86CGP Right to Left, Recommended Table Fabrication, Left Side, Right Side, Front View

Models: AJ-100CE AJ-100CGP AJ-100CS aj-86ce AJ-86CS AJ-64CE AJ-64CS AJ-86CGP

1 60
Download 60 pages 56.57 Kb
Page 24
Image 24
SECTION 1: SPECIFICATION INFORMATION AJ-86 STEAM - RIGHT TO LEFT

16

Issued: 05-02-2006 Revised: 09-

AJ-64 Conveyor Series Technical Manual

 

29-2007

7610-003

 

 

-30-93

 

 

 

Right to Left

 

 

Recommended Table Fabrication

Note: Tub Will Accept

 

 

1634 [425mm]

 

 

 

 

 

 

Rack Rail

Table

 

a Table Flange

 

 

1641 [415mm]

 

Legend

 

 

 

 

 

Up to 24 7/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

A - Machine water inlet 3/4" NPT 180°F

 

 

 

 

 

 

[632 mm]

 

 

 

Hi-temp,140°F Low-temp minimum

 

 

 

 

Use Silicone Sealer

 

 

 

 

O

 

B - Electrical connection

 

 

 

Rack Rail Height

3/4" [19 mm]

 

 

 

 

 

 

Between Table and

 

 

 

 

 

 

 

 

 

 

C - Drain connection 1-1/2" NPT

 

Above Dishtable

Table Turndown

 

 

 

 

 

Tub Lip of Machine to

21" [533 mm]

Prewash Plan View Section

 

D - Vent collar - Optional

 

 

 

1/4" [6mm] - 5/16" [8mm]

Prevent Leakage

Flange 3/4" Max

 

 

E - Vent cowl standard

 

 

 

 

 

 

 

 

 

with Cold Water Thermostat

 

 

 

 

 

 

 

 

 

 

 

 

F - 3/4" NPT Steam connection

 

 

 

 

 

 

 

 

 

 

 

G - 3/4" NPT Condensate return

 

M

 

38 [966mm]

 

 

 

 

 

 

H - Steam electrical connection

 

 

 

 

 

 

 

 

J - 1" NPT Steam connection

 

1

 

1141 [285mm]

K

 

 

 

 

 

 

K - 3/4" Condensate connection

64 [159mm]

 

H

F

 

 

 

 

21 [535mm]

L - 3/4" NPT Incoming 110°F water

 

 

 

 

 

 

 

 

 

connection

 

 

 

 

 

 

 

 

 

 

 

 

25 [637mm]

M - 3/4" NPT 180°F water to dishmachine.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

N - Prewash water inlet 3/4" NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110°F-140°F

 

 

1

[218mm]

J

 

 

 

 

 

 

 

 

O - Cold water thermostat plumbing

82

L

 

 

 

 

 

8 [204mm]

543 [148mm]

 

 

 

 

 

 

connection 3/4" NPT - Optional

1

[345mm]

 

64 [1626mm] Base Unit

22 [557mm]

Floor Sink Or Drain

 

 

 

 

 

1

132

 

 

86 [2182mm] Table to Table

Prewash

 

Note: All vertical dimensions are +/- 1/2"

 

44 [110mm]

2343 [604mm]

 

 

 

With 3" (76 mm)

 

from floor due to adjustable

bullet feet.

 

 

4" (102 mm) wide x 16" (406 mm)

 

94 [2386mm]

 

Minimum Drain Line

 

 

 

 

 

 

84 [2134mm]

 

 

 

 

 

long cutout in Vent Cowl/Splash

 

102 [2589mm] Overall

 

 

 

 

 

 

 

Shield. Shipped with Cover Plate.

 

 

 

 

 

 

With Doors Open

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

47 [1194mm]

 

24 [610mm]

25 [635mm]

 

 

 

 

 

 

 

 

 

 

6621 [1692mm]

A

751

[1919mm]

 

 

43 [1092mm]

 

 

 

 

 

231

[599mm]

21 [533mm]

 

1 [25mm]

 

N

2

 

 

 

 

 

 

 

 

 

 

 

8 [203mm]

 

B

2

 

 

12 [307mm]

3 [79mm]

 

O

6221 [1590mm]

 

A

N

 

B

 

 

4 [102mm]

 

 

 

 

 

6041 [1530mm]

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

7 [178mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

6521 [1665mm]

 

 

 

 

 

 

 

 

 

 

 

E 25 [635mm]

 

 

 

 

 

 

 

 

 

 

 

 

Dish Clearance

 

21 [15mm]

 

43 [1092mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear of

 

J

H

L

121 [316mm]

 

 

 

 

 

 

 

2

 

 

 

 

 

 

Machine

 

 

 

 

 

5343 [1365mm]

 

 

 

Drive

M

 

 

F

 

34 [864mm]

 

 

Unit

 

 

Drive

 

C

101

[266mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit

 

 

2

 

 

 

 

 

 

 

 

1721 [445mm]

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 [152mm]

 

621 [162mm]

 

29 [737mm]

 

1041 [261mm]

 

1041 [261mm]

C

81

[217mm]

 

 

1121 [295mm]

 

10 [254mm]

6 [152mm]

 

 

 

2

 

Left Side

 

 

 

 

 

Right Side

 

 

1534 [400mm]

 

 

 

Front View

 

 

 

 

 

161

[417mm]

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

SECTION 1: SPECIFICATION INFORMATION AJ-86 STEAM - RIGHT TO LEFT

Page 24
Image 24
Jackson AJ-86CGP, AJ-64CS, AJ-64CE, AJ-86CS Right to Left, Recommended Table Fabrication, Left Side, Right Side, Front View