CONTROLS, MOTORS, & BLOWER DRYER SECTION

SECTION 1: SPECIFICATION INFORMATION

ELECTRICAL REQUIREMENTS OF THE JFT

CONTROLS, MOTORS, & BLOWER DRYER SECTION

 

 

 

RINSE

 

TYPICAL

 

 

 

HEATER

TOTAL

ELECTRICAL

VOLTS

PH

HZ

RATINGS

AMPS

CIRCUIT

208

3

60

N/A

44

60 AMP

230

3

60

N/A

42

60 AMP

460

3

60

N/A

21

30 AMP

600

3

60

N/A

19

25 AMP

CONTROLS, MOTORS, (NO BLOWER DRYER SECTION)

 

 

 

RINSE

 

TYPICAL

 

 

 

HEATER

TOTAL

ELECTRICAL

VOLTS

PH

HZ

RATINGS

AMPS

CIRCUIT

208

3

60

N/A

12

15 AMP

230

3

60

N/A

12

15 AMP

460

3

60

N/A

6

15 AMP

600

3

60

N/A

19

25 AMP

FINAL RINSE & BOOSTER HEATER SECTION

 

 

 

RINSE

 

TYPICAL

 

 

 

HEATER

TOTAL

ELECTRICAL

VOLTS

PH

HZ

RATINGS

AMPS

CIRCUIT

208

3

60

27 KW

75

100 AMP

230

3

60

27 KW

68

90 AMP

460

3

60

27 KW

34

45 AMP

600

3

60

27 KW

26

35 AMP

WASH TANK SECTION

 

 

 

WASH

 

TYPICAL

 

 

 

HEATER

TOTAL

ELECTRICAL

VOLTS

PH

HZ

RATINGS

AMPS

CIRCUIT

208

3

60

24KW

77

100 AMP

230

3

60

24KW

70

90 AMP

460

3

60

24KW

35

45 AMP

600

3

60

24KW

27

35 AMP

POWER RINSE TANK SECTION

 

 

 

RINSE

 

TYPICAL

 

 

 

HEATER

TOTAL

ELECTRICAL

VOLTS

PH

HZ

RATINGS

AMPS

CIRCUIT

208

3

60

26 KW

78

100 AMP

230

3

60

26 KW

71

90 AMP

460

3

60

26 KW

35

45 AMP

600

3

60

26 KW

28

35 AMP

JFT Series Technical Manual 7610-002-77-38