Exhaust Requirements

SECTION 1: SPECIFICATION INFORMATION

JFT L-R & R-L LEGEND & EXHAUST FAN DIMENSIONS

Legend

1 - 1-1/2" NPT Machine Drain Connection

(Floor drain - optional to either end)

2 - *Wash Tank Electrical Connection

3 - *Rinse Tank Electrical Connection

4 - *Booster Heater Electrical Connection

5 - *Motor Controls Electrical Connection

6 - 3/4" NPT Incoming Water Connection

7 - Condensate Connection - See Detail

Note:

The condensate removal system built into the dishmachine consists of a fan that will remove 1200 CFM. A single condensate connection must be provided by the installing contractor. This is an indirect connection that must be capable of removing 1200 CFM from the area.

 

Condensate Exhaust Duct

18" [457mm] I.D. Square

Minimum 18" Square (Cross Section 324 Sq. In.)

Deep

Provided by HVAC Contractor

Exhaust Requirements

 

3" [72mm]

- 1200 CFM

 

 

Condensate duct to extended into duct pan.

 

Condensate duct pan mounted on top of

 

dishmachine electrical section.

6'-10" [2083mm] A.F.F.

 

JFT Series Technical Manual 7610-002-77-38

Issued: 03-16-2006 Revised: 09-14-2007