SECTION 5: SERVICE PROCEDURES
VACUUM BREAKER REPAIR PARTS KIT (CONTINUED)
Removing the plunger
6.Your repair kit comes with a new plunger. Examine the old one and ensure that the mating surface is not damaged or cut. Also inspect the rubber seal on the top of the plunger to ensure it is in good condition and not torn.
7.If any of these conditions are present, replace the old plunger with the new one from your kit. Verify that the new plunger is also free from defects. If it is not, contact your Ecolab representative immediately.
8.The plunger should drop into the vacuum breaker and seat. Ensure it is not flipped upside down (the orange seal ring should be up towards the top of the vacuum breaker).
9.Pick up the cap and examine it. With a soft towel, remove any grit, grime or debris that may have gotten caught in the threads of both the cap retainer or the vacuum breaker body. There is an
Replacing the
10.With the new
Examining the seal ring on the plunger
AFTER MAINTENANCE ACTIONS
1. Reconnect the incoming water (if disconnected) and turn on. Then restore power to the unit. Run the unit for at least 10 minutes to ensure there are no leaks. If any prob- lems arise please contact your Ecolab representative.
SPECIAL PARTS
Vacuum breaker repair kit:
For 1/2” NPT order
For 3/4” NPT order
Complete Vacuum Breaker Assembly
For 1/2” NPT order
For 3/4” NPT order
Examining the plunger seating surface
JFT Series Technical Manual
Issued:
31