Remove the thermostat bracket mounting nuts with the 3/8” nutdriver.

SECTION 5: SERVICE PROCEDURES

RINSE REGULATING THERMOSTAT REPLACEMENT

Location of the thermostat bracket (JP-24).

Remove the thermostat bracket mounting nuts with the 3/8” nutdriver.

Pulling the thermostat probe and fitting from the well (Tempstar).

Removing the wires from the thermostat.

Location of the imperial brass fitting (JP-24).

Removing the imperial brass fitting (Tempstar).

5.Attach the jumper wires to the wires that you removed from the old thermostat.

Attaching the jumper wires.