SPECIFICATIONS of the JP-24B/JP-24BF
(21.5) 5.65
(11.4) 3
(65.6°C) 150°F (82.2°C) 180°F
262
28
10
5

SECTION 1: SPECIFICATION INFORMATION

SPECIFICATIONS of the JP-24B/JP-24BF

PERFORMANCE/CAPABILITIES

OPERATING CAPACITY (RACKS/HOUR)

RACKS PER HOUR

DISHES PER HOUR

30

600

ELECTRICAL REQUIREMENTS

WASH MOTOR HP

3/4

NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-trip cir-

GLASSES PER HOUR

OPERATING CYCLE (SECONDS)

WASH TIME

DRAIN TIME

RINSE TIME

TOTAL CYCLE TIME (MINUTES)

600cuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than what is dis- played here. Always verify with your electrical service con- tractor that your circuit protection is adequate and meets all

applicable national and local codes. These numbers are pro-

82

vided in this manual simply for reference and may change

28

without notice at any given time.

 

10

 

2

RINSE

 

TYPICAL

 

 

 

HEATER

TOTAL

ELECTRICAL

 

VOLTS PH HZ RATINGS

AMPS

CIRCUIT

5 MINUTE TIMER OPERATING CYCLE (SECONDS) WASH TIME

DRAIN TIME

RINSE TIME

TOTAL CYCLE TIME (MINUTES)

TANK CAPACITY (LITERS) (GALLONS)

WASH TANK

RINSE TANK

208

1

50

6.7KW

40

50 AMP

230

1

50

8.2KW

43

60 AMP

208

1

50

8.2KW

47

60 AMP

230

1

50

10KW

51

70 AMP

220

1

50

9.15KW

48

60 AMP

208

1

60

6.7KW

39

50 AMP

230

1

60

8.2KW

46

60 AMP

208

1

60

8.2KW

42

60 AMP

230

1

60

10KW

50

70 AMP

460

1

60

480/8.2KW

11

15 AMP

460

1

60

480/9.6KW

14

20 AMP

TEMPERATURES

WASH --- (MINIMUM)

RINSE --- (MINIMUM)

WATER REQUIREMENTS

INLET TEMPERATURE (40° Booster Heater) (82.2°C) 140°F INLET TEMPERATURE (70° Booster Heater) (43.3°C) 110°F

GALLONS PER HOUR

(198.7L) 52.3

WATER LINE SIZE I.P.S. (Minimum)

(1.27 cm) 1/2”

DRAIN LINE SIZE I.P.S. (Minimum)

(3.81 cm) 1 1/2”

FLOW PRESSURE P.S.I.

20A5

FLOW, GALLONS PER MINUTE

(27L) 7.1

NOTE: Always refer to the machine data plate for specific electrical and water requirements. The material provided on this page is for reference only and may be subject to change without notice.

JP-24 Technical Manual 7610-002-49-79 Rev. D

Issued: 03-06-2006 Revised: N/A

3

Page 8
Image 8