ELECTRICAL INSTALLATION INSTRUCTIONS
Control Box Electrical Connection
Back of Unit Showing Chemical Connection Points

SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

ELECTRICAL INSTALLATION INSTRUCTIONS

ELECTRICAL POWER CONNECTION: Electrical and grounding connections must comply with the applicable portions of the National Electrical Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.

Disconnect electrical power supply and place a tag at the disconnect switch to indicate that you are working on the circuit.

The dishmachine data plate is located on the front of the machine. Refer to the data plate for machine operating requirements,

machine voltage, total amperage load and serial number.

Ground Lug

Terminal Block

 

To install the incoming power lines, remove the kick panel. This will require tak- ing a phillips head screwdriver and removing the two screws at the bottom of the kick panel; open the door slightly while carefully lifting the kick panel up and out of the way. Install 3/4” conduit into the pre-punched holes in the back of the control box. Route power wires and connect to power block and grounding lug. Install the service wires (L1 and L2) to the appropriate terminals as they are marked on the terminal block. Install the grounding wire into the lug provided. It is recommended that “DE-OX” or another similar anti-oxidation agent be used on all power connections.

VOLTAGE CHECK: Ensure that the power switch is in the OFF position and apply power to the dishmachine. Check the incoming power at the terminal block and ensure it corresponds to the voltage listed on the data plate. If not, contact a qualified service agency to examine the problem. Do not run the dish- machine if the voltage is too high or too low. Shut off the service breaker and mark it as being for the dishmachine. Advise all proper personnel of any prob- lems and of the location of the service breaker. Replace the control box cover and tighten down the screws.

CHEMICAL CONNECTIONS: All chemical hookup loca- tions are located on the back of the dishmachine. Please refer to the drawing at the right for the correct connection point.

Brass Plug

Rinse Aid Fitting

Detergent Fitting

JP-24 Technical Manual 7610-002-49-79 Rev. D