LEVEL ADJUSTMENT
The Finestra comes factory
NOTE: It is important check the level prior to water testing. The unit must be level for water testing as this helps with the door seal alignment.
If it is necessary to level the bath, start by leveling the outside four legs, then move to the two legs on the door. The unit is preleveled prior to shipment and should not be
Nut (Top)
Rail
Nut (Bottom)
Threaded
Levelintg
Leg
tampered with if not required.
CAUTION: Under no circumstances will it be necessary to remove the levelling feet.
Foot
Leveling Legs
(Floor)
ELECTRICAL CONNECTIONS
All circuits must be protected by a dedicated Ground Fault Circuit Interrupter (GFCI). Refer to the electrical specification for each model on pages
With a #8 solid copper wire, bond the heater to the house electrical panel or approved local bond. A bonding lug is provided on the heater. With another #8 solid copper wire, bond the pump/motor to the house electrical panel or approved local bond. A bonding lug is provided on the pump/motor.
At initial
Danger: Risk of electric shock. Connect only to a circuit protected by a dedicated Ground Fault Circuit Interrupter (GFCI).
Caution: Operating the motor/pump without enough water in the bath can cause leaking and permanent damage to the pump. Before power is applied to the installation, make sure the switch is in the OFF position to avoid pump damage.
It is necessary to install separate dedicated GFCI protected circuits for both duplex receptacles (not provided).
ELECTRICAL CONNECTION
1. | The motor is connector the the Control Box. |
|
2. | The Control Box is connected to the Ozone unit. |
|
3. | The Ozone unit is connected to the power receptacle. |
|
Ozone unit |
NOTE: The heater is conected independently.
Blower | Motor |
|
Blower
Power connector
Motor
|
|
|
|
|
Rapid heater |
| Control box |
| |
|
|
|
| |
Right side of unit |
| Left side of unit |
Jacuzzi Whirlpool Bath: Finestra | Page 13 | FL61000B • 10/07 |