Jacuzzi Whirlpool Spa owner manual Automatic Filter Cycles, Operation, Display Messages

Models: Whirlpool Spa

1 24
Download 24 pages 50.61 Kb
Page 9
Image 9
Automatic Filter Cycles

www.clearcreekspas.com

OPERATION

Mode Function

 

Pressing the

button switches spa operation to

either the ECONOMY or STANDARD mode. In the economy mode, the spa will heat only during the filter cycles and only when the spa water temperature is 20°F below the temperature set point. In the standard mode, the spa will continuously heat to the set temperature.

Automatic Filter Cycles

Your spa will automatically filter itself for 2 hours twice each day. The first filter cycle will begin 1 minute after the spa is energized. The second filter cycle will begin twelve hours after the start of the first cycle. The blower will activate for 30 seconds at the start of each filter cycle to clean out the air channel. The low-speed jets will constantly run during the filter times (unless the high-speed jets are on) and the heater will be enabled.

Display Messages

These are some of the messages you will see on the center display.

Message Meaning

Message Meaning

Economy: The spa is in ECONOMY mode. ECON is flashed alternately with the current temperature and COOL until the spa water is less than 20°F cooler than the set tempera- ture.

Overheat Protection: Spa is deactivated. If a malfunction occurs and the spa water reaches 112°F, the system will completely shut down.

Danger: DO NOT ENTER THE WATER. Turn off all power to the spa and contact your dealer or service organization. Press any panel button to reset.

Flow Switch (Constantly displayed): A pres- sure switch has malfunctioned. Contact your dealer or service organization.

Flow Switch (Flashing): 1) The filter may be plugged. Remove the filter and clean. 2) The amount of water may be inadequate. Be sure the spa is properly filled. 3) A pressure switch has malfunctioned. The spa will operate, but the heater will not activate. Contact your dealer or service organization.

Temperature Set Back: If the spa water is more than 20°F cooler than the temperature set point, the heater will automatically acti- vate. This is a normal spa function; no corrective action is necessary.

Freeze Protection: If a freeze condition is detected, the pump is automatically acti- vated. This is also a normal spa function; no corrective action is necessary.

Open Sensor: Spa is deactivated. The high limit temperature sensor is nonfunctional. This must be repaired by a dealer or service organization.

Open Sensor: Spa is deactivated. The water sensor is nonfunctional. This also must be repaired by a dealer or service organization.