CV-M10BX/CV-M10RS

The resulting video signal will start to be read out after the trigger rising edge. The WEN pulse indicates the start of valid video signal. Refer to timing charts for details.

A new trigger pulse must not be applied before the video read out has been finished.

To use this mode:

Set:

SW1-4 on BX rear to OFF for random trigger. For RS select trigger mode

 

JP12 on PK8206 (BX ver.) or PK8190 (RS ver.) Short for Pulse Width Control

 

JP13 on PK8206 (BX ver.) or PK8190 (RS ver.) OPEN for H Reset

 

JP13 on PK8206 (BX ver.) or PK8190 (RS ver.) Short for H Non Reset

 

SW1-1 through SW1-3 on BX rear to ON (1/10,000) For RS select 1/10,000

 

and SW1 on (BX) PK8206 for Normal shutter.

Note:

For CV-M10RS the selection of Edge Pre-select, Pulse Width Control H Reset and H non-reset cannot be done by

 

RS232C. In Pulse Width Control Mode the shutter speed must be set at 1/10000 sec.

 

(See chapt r 7 and 8 for details)

6.4EdgeINTXSTRIG. UBTimingHDpreselectdiagramHDmodeRESET(Hresetfor Edge)

Pre-select

 

 

WENG

exposuretime

 

 

 

2:1interlaceinfieldaccumulation

 

 

 

VIDEO1

inframeaccumulation

7HD

EIA:247HD

CCIR:291HD

NonVIDEOinterlace2

EdgeVIDEOpre1selectmode(HNonReset)

14HD

EIA:494HD

CCIR:582HD

TRIG

 

 

 

 

EXTUBED

 

 

 

 

XSG

exposuretime

 

 

 

WEN

 

 

 

2:1interlaceinfieldaccumulation

7HD

EIA:247HD

CCIR:291HD

VIDEO1

 

NonVIDEOVIDEOinterlace12 inframeaccumulation

14HD

EIA:494HDCCIR:582HD

- 6 -

Page 9
Image 9
JAI CV-M10 operation manual 7HD, Pre-select