Important Installation Suggestions
1.Chamfer all exposed edges of decorative laminate to prevent damage from chipping,
2.Radius corners of cutout and file to insure smooth edges and prevent comer cracking,
3. Rough edges, inside corners which have not been rounded and forced fits can contribute to cracking of the countertop laminate.
4. Countertop must be supported within 3" of cutout,
On any burner, closing the air shutter too far will cause the flame to become soft and yellow tipped.
Opening the air shutter too wide will cause the flame to blow away from the burner ports. Proper adjustment will produce a sharp, clearly defined, even blue flame,
Pressure Testing
The maximum gas supply pressure for the appliance pressure regulator supplied on this appliance is 14" W.C.
The test pressure for checking this appliance pressure
regulator must be at least 6" W.C. for Natural Gas, and at least t 1" W.C. for LP. It is shipped from the factory set for
Natural Gas at 5" W.C.
This appliance and its individual shutoff valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of 112"PSIG (3.5 k Pa).
This appliance must be isolated from the gas supply
piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2" PSIG (3.5 k Pa).
Low Flame Adjustment
(See Illustration "C")
This appliance is shippedfrom the factory with low and medium flame settingsadjustedfor use with NaturalGas. If further adjustment is necessary, or to
1. Lightburner and set controlknobfor low flame.
2. Remove control knob from valve stem.
3.Insert a slender,
4.Turn center stem adjusting screw to set flame size.
• . . clockwise to reduce.
... counterclockwiseto increase.
5. Replace control knob when adjustment is completed.
Proper adjustment will produce a stable, steady blue flame of minimum size. The final adjustment should be checked by turning knob from high to low several times without extinguishing the flame.
This adjustment, at low setting, will automatically provide the proper flame size at medium setting.
CLOCKWISE
TOREDUCE
Appliance Pressure Regulator
Conversion
(See Illustration "D")
This unit is supplied with a Maxitrol Appliance Pressure Regulator.Followthe instructionsin illustration"D".
MAXlTROL APPLIANCE PRESSURE REGULATOR
| APPLYDOWNWARD |
| FINGERPRESSURE |
| ATDISCEDGESTO |
ER_I LP | REPLACEPIN IN CAP |
CAP | I | _ | APPLY |
|
CONVERT |
|
|
|
|
AND | TI | SIDEWARDFINGER | ||
, |
| NA | OVEPiN | |
NAT _../.," r |
| REMP ESSURETO !LP | ||
_ |
| Ii_FROM | CAP | II_ |
Illustration "D"
Illustration "C" | colJwErRCLOCK'WISE |
| TO INCREASE FLAME |
SIZE