TO CONVERTAPPLIANCEFORUSEWITHNATURALGAS
PropaneGas(LP)To NaturalGas
ConversionInstructions
If this appliance has been converted for use with LP Gas,
each of the following modifications must be performed to convert the unit back to Natural Gas.
Model- JGD8348BDP
Manifold - Natural Gas pressure required - 5" W.C.
Incoming Natural Gas pressure required to appliance pressure regulator - 6" - 7" W.C.
Natural Gas input specified - 56,000 BTU/hr.
A.Replace allorifice hoods - Perform steps 1through 4on page7. Locate the (6) six NaturalGas hoods (withsmall numbersstamped ontheir sides savedfrom the original Natural Gas unit). Page 5 Illustration "E'. The two
hoods with .0520 (#55 orifice) stamped on them are for the left front and left rear burners. The four hoods with
the .0595 (#53 orifice) stamped on them are for the two right burners.
To make these conversion adjustments follow the instructions and illustrations ("A" through "E") pages
B. Invert cap in appliance pressure regulator (see Illustration "D", page 6). With the appliance installed, the appliance pressure regulator is located on the right underside of the appliance at the inlet to the gas manifold. Identify the type of appliance pressure regulator on the unit and follow the instructions in the appropriate illustration.
C. Adjust low flame setting for each burner. Follow the instructions for burner low flame adjustment on page 7 to increase the simmer flame size.
Q
Q
JGD8348BDP
Left Rear (LR) | 8,000 | #55 | .0520 | Green |
Left Front (LF) | 8,000 | #55 | .0520 | Green |
Center Rear (CR) | 10,000 | #53 | .0595 | Brass |
Center Front (CF) | 10,000 | #53 | .0595 | Brass |
Right Rear (RR) | 10,000 | #53 | .0595 | Brass |
Right Front (RF) | 10,000 | #53 | .0595 | Brass |
9