Jenn-Air dimensions To Convertapplianceforusewithpropanegas, Models- JGD8348BDP

Models: JGD8348BDP

1 11
Download 11 pages 12.52 Kb
Page 8
Image 8
TO CONVERTAPPLIANCEFORUSEWITHPROPANEGAS

TO CONVERTAPPLIANCEFORUSEWITHPROPANEGAS

NaturalGasTo PropaneGas (LP)ConversionInstructions

Models- JGD8348BDP

Manifold - Propane Gas pressure required - 10" W.C.

Incoming Propane Gas pressure required to appliance pressure regulator- 11" - 12" W,C.

Propane Conversion Orifice Hoods are supplied with this model.

Propane Gas input specified - 46,000 BTU/hr.

Q

,_ JGD8348BDP

Left Rear (LR)

7500

#66

.033

Zinc

Left Front (LF)

7500

#66

,033

Zinc

Center Rear (CR)

6500

#68

.031

Red

Center Front (CF)

9000

#63

.037

Blue

Right Rear (RR)

6500

#68

.031

Red

Right Front (RF)

9000

#63

.037

Blue