TO CONVERTAPPLIANCEFORUSEWITHPROPANEGAS
NaturalGasTo PropaneGas (LP)ConversionInstructions
Models- JGD8348BDP
Manifold - Propane Gas pressure required - 10" W.C.
Incoming Propane Gas pressure required to appliance pressure regulator- 11" - 12" W,C.
Propane Conversion Orifice Hoods are supplied with this model.
Propane Gas input specified - 46,000 BTU/hr.
Q
,_ JGD8348BDP
Left Rear (LR) | 7500 | #66 | .033 | Zinc |
Left Front (LF) | 7500 | #66 | ,033 | Zinc |
Center Rear (CR) | 6500 | #68 | .031 | Red |
Center Front (CF) | 9000 | #63 | .037 | Blue |
Right Rear (RR) | 6500 | #68 | .031 | Red |
Right Front (RF) | 9000 | #63 | .037 | Blue |