Installation
Technical Data |
| Heating elements rating |
| ||
Dimensions of recess |
| Conventional Oven (Top element+Bottom element) 1,800 W | |||
Height | 580 mm | Top element | 800 | W | |
|
|
| |||
Width | 560 mm | Bottom element | 1,000 | W | |
Depth | 550 mm | Fan Oven | 2,000 | W | |
|
| Inner Grill element | 1,650 | W | |
Dimensions of the oven cavity |
| Full Grill element | 2,450 | W | |
Height | 335 mm | Pizza Oven | 2,000 W/1,000 W | ||
Width | 395 mm | Thermal Grilling | 1,675 | W | |
Depth | 400 mm | ||||
Convection Fan | 25 W | ||||
|
| ||||
Oven capacity | 53 litres | Oven Light | 25 W | ||
|
| ||||
|
| Cooling Fan | 25 W | ||
|
| Total Rating | 2,500 | W | |
|
| Supply voltage (50 Hz) | 230 V |
Electrical Connection
The oven is designed to be connected to 230 V (50 Hz) electricity supply.
The oven has an easily accessible terminal block which is marked as follows:
Letter L | - | Live terminal | |||||||
Letter N | - | Neutral terminal | |||||||
|
|
|
|
|
|
| or E | - | Earth terminal |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical supply must comply to the specifications given below.
For Uk use only
Connection | Min. size | Cable / flex | Fuse |
via | Cable/flex | type |
|
|
|
|
|
• Cooker | 2.5 mm2 | PVC/PVC | 20 A |
Control |
| twin and |
|
Circuit |
| earth |
|
|
|
|
|
It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.
The switch must not break the yellow and green earth cable at any point.
I m p o r t a n t
After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 60°C above the ambient temperature.
Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.
The manufacturer disclaims any responsibility should these safety measures not be carried out.
For Europe use | only |
| |
|
|
|
|
Min. size Cable/flex |
| Cable / flex type | Fuse |
|
|
|
|
2.5 mm2 |
| H07 | 15 A |
|
| H05 |
|
|
| H05 |
|
|
| H05 |
|
|
|
|
|
5