John Lewis JLBIOS602 Installation, Electrical Connection, Technical Data, Heating elements rating

Models: JLBIOS602

1 28
Download 28 pages 20.35 Kb
Page 5
Image 5
Installation

Installation

Technical Data

 

Heating elements rating

 

Dimensions of recess

 

Conventional Oven (Top element+Bottom element) 1,800 W

Height

580 mm

Top element

800

W

 

 

 

Width

560 mm

Bottom element

1,000

W

Depth

550 mm

Fan Oven

2,000

W

 

 

Inner Grill element

1,650

W

Dimensions of the oven cavity

 

Full Grill element

2,450

W

Height

335 mm

Pizza Oven

2,000 W/1,000 W

Width

395 mm

Thermal Grilling

1,675

W

Depth

400 mm

Convection Fan

25 W

 

 

Oven capacity

53 litres

Oven Light

25 W

 

 

 

 

Cooling Fan

25 W

 

 

Total Rating

2,500

W

 

 

Supply voltage (50 Hz)

230 V

Electrical Connection

The oven is designed to be connected to 230 V (50 Hz) electricity supply.

The oven has an easily accessible terminal block which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

 

 

 

 

 

 

 

or E

-

Earth terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical DataTHIS OVEN MUST BE EARTHED

The cable used to connect the oven to the electrical supply must comply to the specifications given below.

For Uk use only

Connection

Min. size
Cable / flex
Fuse

via

Cable/flex
type

 

 

 

 

 

• Cooker

2.5 mm2

PVC/PVC

20 A

Control

 

twin and

 

Circuit

 

earth

 

 

 

 

 

It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.

The switch must not break the yellow and green earth cable at any point.

I m p o r t a n t

After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 60°C above the ambient temperature.

Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.

The manufacturer disclaims any responsibility should these safety measures not be carried out.

For Europe use

only

 

 

 

 

 

Min. size Cable/flex

 

Cable / flex type

Fuse

 

 

 

 

2.5 mm2

 

H07 RN-F, H05 RN-F,

15 A

 

 

H05 RR-F, H05 VV-F,

 

 

 

H05 V2V2-F (T90),

 

 

 

H05 BB-F

 

 

 

 

 

5

Page 5
Image 5
John Lewis JLBIOS602 Installation, Electrical Connection, Technical Data, Heating elements rating, For Uk use only, Fuse