Johnson Controls TM8M/TMLM*MP, YM8M/YMLM*MP UIM-A-0508, Johnson Controls Unitary Products

Models: LM8M/LMLM*MP TM8M/TMLM*MP CM8M/CMLM*MP YM8M/YMLM*MP

1 28
Download 28 pages 19.77 Kb
Page 13
Image 13
Manual background

368261-UIM-A-0508

THERMOSTAT

THERMOSTAT

 

 

*DN22U00124

*PP32U70124

 

 

 

ID MODELS

 

 

TM(8,L)M

 

 

 

 

YM(8,L)M

 

 

 

 

CM(8,L)M

 

 

 

 

LM(8,L)M

 

 

 

 

 

 

 

 

 

 

 

MODULATING

 

 

TWO STAGE

 

 

 

AIR

 

FURNACE

 

 

 

 

 

CONDITIONER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

C

24 – Volt Common

24 – Volt Common

 

 

Y1

Y1

First Stage Compressor

First Stage Compressor

 

 

R

R

24 – Volt Hot

24 – Volt Hot

(Heat XFMR)

(Heat XFMR)

G

G

Fan

Fan

 

 

E/W1

E/W1

First Stage Heat

Emergency Heat

 

 

W2

AUX

Second Stage Heat

Auxiliary Heat

 

 

R

R

24 – Volt Hot

24 – Volt Hot

(Cool XFMR)

(Cool XFMR)

 

 

Y2

Y2

Second Stage

Second Stage

Compressor

Compressor

MODULATING

FURNACE CONTROL

C

24 – Volt Common

Y1

Single

Stage Compressor

R

24 – Volt Hot

G

Fan

W

Modulating Heat

Y/Y2

Second or Full

Stage Compressor

O

Reversing Valve

Energized in Cool

LO COMP

Single Stage

Compressor (OUT)

HI COMP

Second Stage

Compressor (OUT)

DHUM

1

C

24 – Volt Common

Y1

First Stage Compressor

R

24 – Volt Hot

Y2

Second Stage

Compressor

2

Connection of the “C”

terminal, 24-volt common is optional when used with batteries

Thermostat Installer Setup

1-System Type-must

be set to 6-2 Heat/2 Cool Multistage Conventional

Thermostat Installer Setup

15-Compressor Protection

-must be set to 5

2

External Humidistat

(Optional)

Open on Humidity Rise

Connection of the “C”

terminal, 24-Volt common is optional when used with batteries

Thermostat Installer Setup 0170-System Type-must be set to 8-2 Heat/2 Cool Multistage Conventional

Part Number:

S1-2HU16700124

Dehumidification-

Open on Humidity Rise

Move HUMIDISTAT

jumper to “YES”

if humidistat is to be used.

Part Numbers:

1

SAP = Legacy

FIGURE 21: Thermostat Chart - Two Stage Air Conditioner – Variable Speed or PSC Modulating Furnace

Johnson Controls Unitary Products

13

Page 13
Image 13
Johnson Controls TM8M/TMLM*MP, YM8M/YMLM*MP, LM8M/LMLM*MP, CM8M/CMLM*MP UIM-A-0508, Johnson Controls Unitary Products