Johnson Controls LM8M/LMLM*MP, YM8M/YMLM*MP, TM8M/TMLM*MP, CM8M/CMLM*MP UIM-A-0508, Thermostat

Models: LM8M/LMLM*MP TM8M/TMLM*MP CM8M/CMLM*MP YM8M/YMLM*MP

1 28
Download 28 pages 19.77 Kb
Page 14
Image 14
Manual background

368261-UIM-A-0508

THERMOSTAT

*PP11C70224

 

ID MODELS

 

 

 

TM(8,L)M

 

 

 

 

YM(8,L)M

 

 

 

 

CM(8,L)M

 

 

 

 

LM(8,L)M

 

 

 

 

 

 

 

 

 

 

 

MODULATING

 

 

TWO STAGE

 

 

 

AIR

 

FURNACE

 

 

 

 

 

CONDITIONER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

Full Stage Compressor

RH

24 – Volt Hot

(Heat XFMR)

G

Fan

RC

24 – Volt Hot

(Cool XFMR)

 

W

 

 

 

 

Full Stage Heat

 

 

 

 

 

 

 

 

 

HM1

 

 

 

 

Humidistat

 

 

 

 

 

 

 

 

 

 

 

 

 

2

External Humidistat

 

 

 

(Optional)

 

 

 

 

 

 

 

 

Open on Humidity Rise

 

 

 

 

 

 

 

MODULATING

FURNACE CONTROL

C

24 – Volt Common

Y1

Single

Stage Compressor

R

24 – Volt Hot

G

Fan

W

Modulating Heat

Y/Y2

Second or Full

Stage Compressor

O

Reversing Valve

Energized in Cool

LO COMP

Single Stage

Compressor (OUT)

HI COMP

Second Stage

Compressor (OUT)

DHUM

Dehumidification-

Open on Humidity Rise

1

C

24 – Volt Common

Y1

First Stage Compressor

R

24 – Volt Hot

Y2

Second Stage

Compressor

Clipping Jumper W914 for electric heat on thermostat is not necessary

2Part Number:

S1-2HU16700124

Move HUMIDISTAT

jumper to “YES”

if humidistat is to be used.

Part Numbers:

1

SAP = Legacy

FIGURE 22: Thermostat Chart - Two Stage Air Conditioner with Single Stage Thermostat – Variable Speed or PSC Modulating Furnace

14

Johnson Controls Unitary Products

Page 14
Image 14
Johnson Controls LM8M/LMLM*MP, YM8M/YMLM*MP, TM8M/TMLM*MP, CM8M/CMLM*MP installation manual UIM-A-0508, Thermostat