OSLO F500 WOODSTOVE CLEARANCES

 

 

UNPROTECTED SURFACE

PROTECTED SURFACE NFPA 211

 

STOVE CLEARANCES

PARALLEL INSTALLATION

PARALLEL INSTALLATION

 

 

 

SIDE

REAR

CORNER*

SIDE

REAR

 

CORNER*

 

Stove-no heatshield

14" A

18" B

13" C

6" D

12" E

 

9" F

 

Single wall pipe

355mm

460mm

330mm

150mm

300mm

230mm

 

 

 

 

 

 

 

 

 

 

 

Stove-with rear heatshield

14" G

10" H

9" I

6" J

10” K

 

9" L

 

Single wall pipe

355mm

255mm

230mm

150mm

255mm

230mm

 

 

 

 

 

 

 

 

 

 

 

 

Stove-with rear heatshield

14" M

6" N

 

9" O

6" P

6" Q

 

6" R

 

with connector shield

355mm

150mm

230mm

150mm

150mm

150mm

 

 

 

 

 

 

 

 

 

 

 

 

Stove-rear heatshield

14" S

6" T

 

9" U

6" V

6" W

 

6" X

 

with double wall pipe

355mm

150mm

230mm

150mm

150mm

150mm

 

 

 

 

 

 

 

 

 

 

CONNECTOR

UNPROTECTED SURFACE

PROTECTED SURFACE NFPA 211

 

CLEARANCES (pipe)

VERTICAL INSTALLATION

VERTICAL INATALLATION

 

Single wall

 

18"

 

 

 

12"

 

 

 

with no heatshields

 

460mm

 

 

300mm

 

 

 

 

 

 

 

 

 

 

 

 

 

Single wall

 

6"

 

 

 

6"

 

 

 

with connector shields

 

150mm

 

 

150mm

 

 

 

 

 

 

 

 

 

 

 

 

 

Double wall pipe

 

6"

 

 

 

6"

 

 

 

 

 

 

150mm

 

 

150mm

 

 

 

 

 

 

 

 

 

 

 

 

 

UNPROTECTED SURFACE

PROTECTED SURFACE NFPA 211

 

 

 

HORIZONTAL INSTALLATION

HORIZONTAL INSTALLATION

 

 

 

 

 

 

 

 

 

Single wall connector

 

18"

460mm

 

12"

300mm

 

 

 

 

 

 

 

 

 

 

 

Double wall Pipe

 

6"

150mm

 

6"

150mm

 

 

 

 

 

 

 

 

 

 

MANTEL AND TRIM

Stove to 1" thick or less, side trim

 

12"

300mm

 

CLEARANCES

 

 

 

 

 

 

 

 

 

 

 

Stove to 1" thick or less, top trim

 

16"

410mm

 

 

 

Stove to mantel- maximum mantel depth 12"

30"

765mm

 

*ATTENTION: STOVE AND PIPE CLEARANCES MUST BOTH BE TAKEN INTO CONSIDERATION. THE GREATER CLEARANCE DICTATES THE STOVE’S POSITION.

*USE OF THE LEFT SIDE LOAD DOOR IS PROHIBITED IN ALCOVE AND CORNER INSTALLATIONS.

12

Page 12
Image 12
Jotul F 500 operating instructions Oslo F500 Woodstove Clearances