Jotul GF300 BV manual Fuel Conversion Procedure, Avertisement

Models: GF300 BV

1 28
Download 28 pages 46.26 Kb
Page 11
Image 11
Fuel Conversion

Fuel Conversion

The GF 300 BV gas stove is shipped from the factory equipped to burn NATURAL GAS only. If PROPANE gas is to be used as fuel, the appliance must first be converted for use with propane. Use Propane Conversion Kit

155592, supplied with the appliance.

Order and install NG Conversion Kit 155593 to change back to use with natural gas.

WARNING:

THE CONVERSION KIT IS TO BE INSTALLED BY AN AUTHORIZED JØTUL SERVICE TECHNICIAN IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTION AND ALL CODES AND REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR PROPERTY DAMAGE. THE QUALIFIED AGENCY PERFORMING THIS WORK ASSUMES RESPONSIBILITY FOR THIS CONVERSION.

IN CANADA:

THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE RE- QUIREMENTS OF THE PROVINCIAL AU- THORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIRE- MENTS OF THE CAN1-B149.1 AND .2 INSTALLATION CODE.

AVERTISEMENT:

Cet equipement de conversion sera installe par une agence qualkfiee de service conformenment aux instructions du fabricant et toutes exigences et codes applecables de l’autorises avoir la juridiction. Si l’informaiton dans cette Instruc- tion n’est pas suivie exactement, un feu, explo- sion ou production de protoxyde de carbone peut resulter le dommages causer de propriete, perte ou blessure personnelle de vie. L’agence qualifiee’ de service est esponsable de l’installation propre de cet equipement. L’installation n’est pas propre et complete jusqu’a l’operation de l’appareil converti est cheque suivant les criteres etablis dans les instructions de proprietaire provisionnees avec l’equipement.

Tools required:

1/2” open ended wrench or deep-well socket, Torx T20 or slotted screwdriver, 4 mm allen wrench.

Conversion Kit Contents:

1, regulator tower labeled for propane

3, regulator tower screws

1, burner orifice (#39 for NG, #53 for LPG)

1, pilot orifice (#51 for NG, #30 for LPG)

Label A - to be completed and applied to the back of the stove

Label B - apply to the stove’s Rating Plate

Small valve label - apply to valve body

Conversion instructions are also shipped in the stove with the conversion kit.

Fuel Conversion Procedure

1.Turn off gas supply to stove.

2.Remove the stove Top Plate.

3.Disengage the two Glass Frame Latches at the top of the firebox. See illustration on page 5. Carefully lift the glass panel up and out of the stove.

4.If installed, remove the Embers and Log Set using care not to damage the fragile log parts.

5.Lift out the Burner Skirt shown in fig.11.

6.Reach under the stove and remove the Air Shutter wingnut from its stud. As you face the right side, it is the one closest to you. See fig. 12.

Burner Skirt

Figure 11. Lift and remove the Burner Skirt from within the firebox.

Open Close

Figure 12. Locate and remove the Air Shutter wingnut from under the right side of the stove.

11