Optional Blower # 155620
CONNECT THE GAS SUPPLY TO THE
STOVE BEFORE INSTALLING THIS
BLOWER. IF NECESSARY, USE A 90°
ELBOW OFF THE GAS VALVE TO CREATE
ADEQUATE GAS LINE CLEARANCE.
BE SURE ALL WIRE CONNECTIONS
HAVE BEEN MADE BEFORE
CONNECTING TO POWER SUPPLY.
1.Unpack and check the contents of the blower kit. Contact your dealer if any damage is evident or parts are missing. See fig. 33.
2.Attach the Snapstat Bracket to the studs located underneath the stove in the middle of the firebox floor using the two M6 hex nuts and a 10 mm wrench. See fig. 34.
3.Attach the Blower to the stove with the screen opening to the rear using the two M6 flange head hex bolts as shown in fig. 35.
4.Attach either Snapstat wire connector to either Snapstat terminal. See fig. 35.
5.Install the Snapstat by sliding it all the way into the slot in the Snapstat Bracket as shown in fig. 34.
6.Connect the female Control Switch
7.Connect power cord to the nearest outlet.
THIS BLOWER MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE CURRENT ANSI/ NFPA 70, NATIONAL ELECTRICAL CODE OR CSA
THIS UNIT IS SUPPLIED WITH A
ALWAYS DISCONECT THE POWER
SUPPLY WHEN PERFORMING ANY
SERVICE ON THE FIREPLACE
INSERT.
5
4
1 | 6 |
2
3
| 7 |
Contents | Tools Required |
1. Blower | • 10 mm wrench |
2.Snapstat Wire Harness
3.Control Switch Wire Harness
4.Snapstat
5.Snapstat Bracket
6.M6 Flange Nuts, (2)
7.M6 x 12 Hex Bolts, (2)
Figure 33. Blower Kit Components
Snapstat
Bracket
Hex Head
Flange Nuts
Figure 34. Attach Snapstat Bracket.
20