Jotul GF300 BV Input Rates, Suggested Tools for Installation and Service, Natural Gas, Propane

Models: GF300 BV

1 28
Download 28 pages 46.26 Kb
Page 4
Image 4
GF 300 BV Allagash Specifications

GF 300 BV Allagash Specifications

The Jøtul GF300 BV Allagash is a atmospherically- vented gas fireplace heater designed only for vertical venting directly to the outside of the house, using listed, Type B-vent pipe.

Input Rates

Natural Gas

26,000 BTU/hr. maximum input

15,000 BTU/hr. minimum input

Propane

26,000 BTU/hr. maximum input

13,500 BTU/hr. minimum input

Inlet Pressure:

MIN

MAX

Natural Gas:

5.0 WC (1.24 kPa)

7.0 WC (1.74 kPa)

Propane:

12.0 WC (2.99 kPa)

14.9 WC (3.71 kPa)

Manifold Pressure: MIN

MAX

Natural Gas:

1.2 WC (.30 kPa)

3.8 WC (.95 kPa)

Propane:

2.9 WC (.722 kPa)

11.0 WC (2.74 kPa)

Piezo Ignitor / Standing Pilot

C

L

11 1/2”

292 mm Input Rates

4 1/2”

114 mm

C

L

16 1/2”

420 mm

23”

584 mm

27 3/4”

705 mm

22 1/4”

565 mm

THIS FIREPLACE IS SHIPPED FROM THE FACTORY FOR USE WITH NATURAL GAS ONLY. FOR USE WITH PROPANE, THE APPLIANCE MUST FIRST BE CONVERTED USING #155592 FUEL CONVERSION KIT PROVIDED. CONVERSION SHOULD BE MADE BEFORE THE APPLIANCE IS INSTALLED. SEE PG. 11.

Suggested Tools for

Installation and Service

External regulator (for Propane only)

Piping which complies with local code

Manual shutoff valve (T-Handle in Massachusetts)

Sediment trap - if required by code

Tee joint

Pipe wrench

Pipe sealant

10 mm open end wrench

1/2”, 7/16” open end wrench or deep socket

Phillips head screwdriver

Flat head screwdriver

1/4” nut driver

4 mm allen wrench

Gloves

Safety glasses

Torx T20 screwdriver

Leak test solution

Reciprocating Saw

Power Drill

With Short Legs, reduce height by 2 1/4” ( 51 mm)

C

L

Top

ExitFlue

Collar

25”

635 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear

 

Exit

Top

Plate

 

 

 

 

 

 

 

21

5/8 ”

27

3/4”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

550

mm

705

mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13”

330 mm

4

Page 4