Jotul GF300 BV Installing Decorative Pipe, System Check, Spill Switch, Decorative pipe attachment

Models: GF300 BV

1 28
Download 28 pages 46.26 Kb
Page 17
Image 17
Installing Decorative Pipe

Installing Decorative Pipe

The use of decorative pipe is optional. No decorative pipe is included with the Jøtul GF 300 BV Allagash, however, four locator brackets are included with the stove in the hardware bag. The brackets are used to center the decorative pipe over the draft hood on which the pipe rests. Follow the procedure below to attach the brackets to the stove.

1.Remove the four 1/4” hex head screws that attach the 4” Flue Collar to the draft hood, but do not remove the Flue Collar. See Figure 27.

2.Align the “L”- shaped pipe brackets with the holes on the Flue Collar and attach using the four 1/4” hex head screws, located in the Misc. Hardware Bag.

Reminder: Do not use single wall stove pipe as the vent pipe on this appliance.

Spill

Switch

Figure 27. Decorative pipe attachment.

System Check

1.PURGING THE GAS LINE: When lighting the appli- ance for the first time, it will take a few moments to clear the gas line of air. Once this purge is complete, the appliance will operate as described in the lighting instructions. See the inside back cover of this manual or the stove Rating Plate attached the bottom of the stove. Subsequent burner starts will not require purging the gas line unless the supply line is shut off.

2.PILOT FLAME: You can monitor the pilot flame through the view port located at the rear of the Right Log. See fig. 28. The pilot flame should be steady - not lifting or floating. The flame should be blue in color around the pilot hood, with traces of yellow toward the outer edges.

The pilot flame should engulf the top 3/8” of the thermopile (to generate millivolt current) and the top 1/8” of the thermocouple. The pilot flame should project out of the pilot hood 1” at all three ports. See fig. 28.

3.BURNER ADJUSTMENT: This stove is equipped with a variable gas control valve that allows easy adjust- ment of the flame height appearance and heat output. To adjust the flame between the HI and LOW setting, rotate the HI/LOW knob, located in the center of the valve face. Fire intensity can be adjusted up to 50% between the LOW and HIGH settings. See fig. 29.

NO SMOKE OR SOOT SHOULD BE PRESENT. CHECK LOG PLACEMENT IF ANY SOOT OR SMOKE IS PRESENT. IF SOOT OR SMOKE PERSISTS, THE AIR SHUTTER MAY NEED TO BE ADJUSTED.

See Air Shutter/Flame Appearance section of this manual for proper air shutter settings and adjust- ments. Note: the more offsets there are in the vent system, the greater the need for an air shutter adjustment. See page 16.

 

1”

 

 

(25mm)

3/8”

1/8”

 

 

(8mm)

(3mm)

 

Min.

Min.

 

 

Figure 28. Proper pilot flame appearance.

17

Page 17
Image 17
Jotul GF300 BV manual Installing Decorative Pipe, System Check, Spill Switch, Decorative pipe attachment